Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,567

matching recommendations
Reset
SIC 347 Metal Services, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0377 # 01 Y:1996 01 1996 TREAT AND REUSE RINSE WATERS $70,000 $198,000 Not Implemented
MA0377 # 02 Y:1996 02 1996 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $6,407 $3,770 Not Implemented
MA0377 # 03 Y:1996 03 1996 PAY UTILITY BILLS ON TIME $3,363 $0 Implemented
MA0377 # 04 Y:1996 04 1996 INSULATE BARE EQUIPMENT $1,650 $1,220 Not Implemented
MA0377 # 05 Y:1996 05 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $434 $174 Not Implemented
UM0065 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $293 $300 Not Implemented
UM0065 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,223 $5,402 Not Implemented
UM0065 # 03 Y:1996 03 1996 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $464 $990 Not Implemented
UM0065 # 04 Y:1996 04 1996 RECOVER AND REUSE WASTE MATERIAL $42,447 $990 Not Implemented
UM0062 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $616 $718 Implemented
UM0062 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,893 $4,042 Implemented
UM0062 # 03 Y:1996 03 1996 OPTIMIZE PLANT POWER FACTOR $10,881 $250 Implemented
UM0062 # 04 Y:1996 04 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,611 $3,000 Not Implemented
UM0062 # 05 Y:1996 05 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $701 $100 Implemented
UM0062 # 06 Y:1996 06 1996 USE SYNTHETIC LUBRICANT $1,533 $658 Implemented
UM0062 # 07 Y:1996 07 1996 TREAT AND REUSE RINSE WATERS $3,084 $0 Not Implemented
DS0060 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,522 $18,920 Implemented
DS0060 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,272 $2,628 Not Implemented
DS0060 # 03 Y:1996 03 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,581 $220 Implemented
DS0060 # 04 Y:1996 04 1996 INSULATE BARE EQUIPMENT $4,872 $7,925 Not Implemented
DS0060 # 05 Y:1996 05 1996 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $5,958 $4,750 Implemented
DS0060 # 06 Y:1996 06 1996 RECOVER AND REUSE COOLING WATER $11,410 $1,100 Implemented
UD0498 # 01 Y:1996 01 1996 TREAT AND REUSE RINSE WATERS $6,700 $2,000 Not Implemented
UD0498 # 02 Y:1996 02 1996 ELIMINATE/REDUCE AN OPERATION $2,200 $600 Not Implemented
UD0498 # 03 Y:1996 03 1996 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $866 $0 Implemented