Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,529
matching recommendationsSIC | 3471 | Plating And Polishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DS0060 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,581 | $220 | Implemented |
DS0060 # 04 Y:1996 | 04 | 1996 | INSULATE BARE EQUIPMENT | $4,872 | $7,925 | Not Implemented |
DS0060 # 05 Y:1996 | 05 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $5,958 | $4,750 | Implemented |
DS0060 # 06 Y:1996 | 06 | 1996 | RECOVER AND REUSE COOLING WATER | $11,410 | $1,100 | Implemented |
UD0498 # 01 Y:1996 | 01 | 1996 | TREAT AND REUSE RINSE WATERS | $6,700 | $2,000 | Not Implemented |
UD0498 # 02 Y:1996 | 02 | 1996 | ELIMINATE/REDUCE AN OPERATION | $2,200 | $600 | Not Implemented |
UD0498 # 03 Y:1996 | 03 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $866 | $0 | Implemented |
UD0498 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $656 | $700 | Not Implemented |
UD0498 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,731 | $6,298 | Not Implemented |
SD0150 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $18,102 | $21,570 | Implemented |
SD0150 # 02 Y:1996 | 02 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,242 | $3,920 | Implemented |
SD0150 # 03 Y:1996 | 03 | 1996 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $10,042 | $4,160 | Implemented |
SD0150 # 04 Y:1996 | 04 | 1996 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,408 | $3,077 | Implemented |
SD0150 # 05 Y:1996 | 05 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,368 | $5,825 | Not Implemented |
SD0150 # 06 Y:1996 | 06 | 1996 | MINIMIZE WATER USAGE | $7,565 | $3,410 | Implemented |
SD0150 # 07 Y:1996 | 07 | 1996 | USE PRECIPITATING AGENTS IN WASTE WATER TREATMENT THAT PRODUCE THE LEAST QUANTITY OF WASTE | $34,791 | $5,000 | Implemented |
DS0051 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $305 | $1,149 | Not Implemented |
DS0051 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,084 | $3,765 | Not Implemented |
DS0051 # 03 Y:1996 | 03 | 1996 | INSULATE BARE EQUIPMENT | $1,434 | $1,257 | Implemented |
DS0051 # 04 Y:1996 | 04 | 1996 | TREAT AND REUSE RINSE WATERS | $8,506 | $17,190 | Implemented |
SD0146 # 01 Y:1996 | 01 | 1996 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $857 | $150 | Implemented |
SD0146 # 02 Y:1996 | 02 | 1996 | INSULATE BARE EQUIPMENT | $530 | $659 | Implemented |
SD0146 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $515 | $564 | Implemented |
SD0146 # 04 Y:1996 | 04 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $373 | $710 | Implemented |
SD0146 # 05 Y:1996 | 05 | 1996 | INSTALL OCCUPANCY SENSORS | $595 | $394 | Implemented |