Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
502
matching recommendationsSIC | 3479 | Metal Coating And Allied Services |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0459 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,650 | $2,070 | Implemented |
CO0459 # 10 Y:2000 | 10 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $600 | $0 | Implemented |
DS0154 # 01 Y:2000 | 01 | 2000 | INSULATE BARE EQUIPMENT | $1,239 | $864 | Implemented |
DS0154 # 04 Y:2000 | 04 | 2000 | RECYCLE CLEANING SOLVENT AND REUSE | $18,740 | $17,676 | Implemented |
DS0154 # 05 Y:2000 | 05 | 2000 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $3,521 | $1,336 | Implemented |
DS0154 # 06 Y:2000 | 06 | 2000 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $4,884 | $0 | Implemented |
SD0230 # 01 Y:1999 | 01 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,090 | $4,048 | Implemented |
SD0230 # 05 Y:1999 | 05 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $83,680 | $0 | Implemented |
SD0230 # 07 Y:1999 | 07 | 1999 | ELIMINATE PRACTICE OF MIXING WASTE STREAMS | $27,200 | $0 | Implemented |
SD0230 # 08 Y:1999 | 08 | 1999 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $0 | $2,410 | Implemented |
MA0441 # 01 Y:1999 | 01 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $21,168 | $5,704 | Implemented |
MA0441 # 02 Y:1999 | 02 | 1999 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $43,200 | $3,000 | Implemented |
MA0441 # 05 Y:1999 | 05 | 1999 | UPGRADE OBSOLETE EQUIPMENT | $789 | $0 | Implemented |
MA0441 # 06 Y:1999 | 06 | 1999 | INSULATE BARE EQUIPMENT | $632 | $2,250 | Implemented |
HO0200 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,818 | $7,776 | Implemented |
HO0200 # 02 Y:1999 | 02 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,223 | $3,065 | Implemented |
HO0200 # 05 Y:1999 | 05 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $7,395 | $4,800 | Implemented |
UD0557 # 01 Y:1998 | 01 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $42,942 | $12,000 | Implemented |
UD0557 # 02 Y:1998 | 02 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $60,203 | $0 | Implemented |
SD0201 # 01 Y:1998 | 01 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,033 | $1,033 | Implemented |
SD0201 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,892 | $6,734 | Implemented |
SD0201 # 03 Y:1998 | 03 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $1,393 | $300 | Implemented |
SD0201 # 04 Y:1998 | 04 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $13,056 | $0 | Implemented |
SD0201 # 05 Y:1998 | 05 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $22,080 | $0 | Implemented |
HO0181 # 03 Y:1998 | 03 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $532 | $325 | Implemented |