Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

171

matching recommendations
Reset
SIC 349 Misc. Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0527 # 09 Y:2016 09 2016 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $581 $1,275 Implemented
WV0527 # 03 Y:2016 03 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,268 $2,530 Implemented
WV0527 # 08 Y:2016 08 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,044 $165 Implemented
UD0927 # 02 Y:2015 02 2015 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $5,025 $0 Implemented
UD0927 # 03 Y:2015 03 2015 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,022 $300 Implemented
WV0469 # 02 Y:2013 02 2013 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $11,090 $1,989 Implemented
WV0469 # 04 Y:2013 04 2013 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,996 $0 Implemented
WV0469 # 06 Y:2013 06 2013 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $5,514 $1,000 Implemented
WV0469 # 09 Y:2013 09 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,378 $70 Implemented
WV0469 # 07 Y:2013 07 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,550 $4,036 Implemented
WV0469 # 11 Y:2013 11 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $314 $56 Implemented
UD0841 # 18 Y:2011 18 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $2,133 $2,098 Implemented
UD0841 # 05 Y:2011 05 2011 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $43,664 $0 Implemented
UD0841 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $88,915 $80,000 Implemented
UD0841 # 17 Y:2011 17 2011 INSTALL AUTOMATIC STACK DAMPER $20,941 $600 Implemented
UD0841 # 15 Y:2011 15 2011 ISOLATE HOT OR COLD EQUIPMENT $33,356 $2,000 Implemented
UD0841 # 14 Y:2011 14 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $64,796 $20,000 Implemented
UD0841 # 13 Y:2011 13 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $417 $1,012 Implemented
UD0841 # 10 Y:2011 10 2011 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $42,803 $110,624 Implemented
UD0841 # 06 Y:2011 06 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $29,362 $500 Implemented
UD0841 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $50,283 $40,000 Implemented
UD0841 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,101 $30,000 Implemented
UD0823 # 15 Y:2010 15 2010 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $355 $25 Implemented
UD0823 # 10 Y:2010 10 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $524 $25 Implemented
UD0823 # 06 Y:2010 06 2010 INSTALL OCCUPANCY SENSORS $17,201 $7,375 Implemented