Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,321
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0205 # 06 Y:2002 | 06 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $932 | $1,000 | Implemented |
UM0204 # 02 Y:2002 | 02 | 2002 | OPTIMIZE PLANT POWER FACTOR | $2,700 | $4,970 | Implemented |
UM0204 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,220 | $1,220 | Implemented |
UM0204 # 04 Y:2002 | 04 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,160 | $500 | Implemented |
UM0204 # 06 Y:2002 | 06 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $330 | $375 | Implemented |
IA0285 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,274 | $458 | Implemented |
IA0285 # 04 Y:2002 | 04 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $39,507 | $800 | Implemented |
IA0285 # 05 Y:2002 | 05 | 2002 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $46,580 | $320 | Implemented |
IA0285 # 06 Y:2002 | 06 | 2002 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $12,642 | $3,424 | Implemented |
IA0285 # 07 Y:2002 | 07 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,018 | $7,500 | Implemented |
SD0287 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,881 | $1,440 | Implemented |
SD0287 # 04 Y:2002 | 04 | 2002 | USE POWER DURING OFF-PEAK PERIODS | $30,695 | $0 | Implemented |
SD0287 # 07 Y:2002 | 07 | 2002 | INSTALL OCCUPANCY SENSORS | $3,635 | $2,800 | Implemented |
MS0192 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,415 | $443 | Implemented |
MS0192 # 02 Y:2001 | 02 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,993 | $1,000 | Implemented |
MS0192 # 03 Y:2001 | 03 | 2001 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,056 | $50 | Implemented |
MS0192 # 05 Y:2001 | 05 | 2001 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,153 | $3,127 | Implemented |
IC0020 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,536 | $1,800 | Implemented |
IC0020 # 02 Y:2001 | 02 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $488 | $0 | Implemented |
IC0020 # 03 Y:2001 | 03 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $325 | $735 | Implemented |
LL0118 # 02 Y:2001 | 02 | 2001 | INSTALL OCCUPANCY SENSORS | $10,056 | $297 | Implemented |
LL0118 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,379 | $2,190 | Implemented |
LL0118 # 05 Y:2001 | 05 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $36,180 | $0 | Implemented |
LL0118 # 06 Y:2001 | 06 | 2001 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $15,884 | $456 | Implemented |
SU0119 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $930 | $0 | Implemented |