Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
160
matching recommendationsSIC | 3495 | Wire Springs |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0550 # 03 Y:1998 | 03 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $8,393 | $1,945 | Implemented |
OK0550 # 04 Y:1998 | 04 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,343 | $4,000 | Implemented |
OK0550 # 05 Y:1998 | 05 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $18,120 | $0 | Implemented |
OK0550 # 06 Y:1998 | 06 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,888 | $9,700 | Not Implemented |
OK0550 # 07 Y:1998 | 07 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,071 | $8,400 | Implemented |
OK0550 # 08 Y:1998 | 08 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,920 | $3,006 | Not Implemented |
OK0550 # 09 Y:1998 | 09 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $518 | $1,610 | Not Implemented |
OK0550 # 10 Y:1998 | 10 | 1998 | INSULATE BARE EQUIPMENT | $197 | $134 | Implemented |
UM0111 # 01 Y:1998 | 01 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,215 | $300 | Implemented |
UM0111 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $289 | $844 | Implemented |
UM0111 # 03 Y:1998 | 03 | 1998 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $894 | $3,212 | Not Implemented |
UM0111 # 04 Y:1998 | 04 | 1998 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,181 | $1,300 | Not Implemented |
UM0111 # 05 Y:1998 | 05 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $694 | $4,000 | Not Implemented |
UM0111 # 06 Y:1998 | 06 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $580 | $0 | Implemented |
MS0087 # 01 Y:1997 | 01 | 1997 | OPTIMIZE PLANT POWER FACTOR | $5,870 | $1,500 | Implemented |
MS0087 # 02 Y:1997 | 02 | 1997 | DISCONNECT BALLASTS | $313 | $150 | Implemented |
MS0087 # 03 Y:1997 | 03 | 1997 | USE SYNTHETIC LUBRICANT | $1,944 | $275 | Implemented |
MS0087 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,232 | $7,102 | Implemented |
MS0087 # 05 Y:1997 | 05 | 1997 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $1,607 | $561 | Implemented |
MS0087 # 06 Y:1997 | 06 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,564 | $11,519 | Not Implemented |
MS0087 # 07 Y:1997 | 07 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,400 | $0 | Implemented |
MS0087 # 08 Y:1997 | 08 | 1997 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $46,844 | $20,800 | Not Implemented |
ND0162 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,484 | $11,590 | Not Implemented |
ND0162 # 02 Y:1993 | 02 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $16,677 | $9,940 | Not Implemented |
ND0162 # 03 Y:1993 | 03 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $8,311 | $4,500 | Implemented |