Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
505
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0471 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $710 | $460 | Implemented |
CO0471 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $110 | $0 | Implemented |
CO0471 # 04 Y:2000 | 04 | 2000 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,810 | $0 | Implemented |
CO0471 # 05 Y:2000 | 05 | 2000 | CONVERT TO ELECTROSTATIC POWDER COATING | $73,840 | $690,300 | Not Implemented |
CO0450 # 01 Y:1999 | 01 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,280 | $60,960 | Not Implemented |
CO0450 # 02 Y:1999 | 02 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,800 | $15,000 | Implemented |
CO0450 # 03 Y:1999 | 03 | 1999 | PURCHASE APPROPRIATELY SIZED MATERIAL | $1,580 | $0 | Not Implemented |
CO0444 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,280 | $1,000 | Implemented |
CO0444 # 02 Y:1999 | 02 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,560 | $450 | Not Implemented |
CO0444 # 03 Y:1999 | 03 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $600 | $0 | Implemented |
CO0444 # 04 Y:1999 | 04 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $19,000 | $21,600 | Not Implemented |
CO0444 # 05 Y:1999 | 05 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $230 | $0 | Implemented |
CO0443 # 01 Y:1999 | 01 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,960 | $0 | Implemented |
CO0443 # 02 Y:1999 | 02 | 1999 | REDUCE VENTILATION AIR | $11,050 | $12,600 | Not Implemented |
CO0443 # 03 Y:1999 | 03 | 1999 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $7,900 | $250 | Implemented |
CO0443 # 04 Y:1999 | 04 | 1999 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $5,760 | $2,000 | Implemented |
CO0443 # 05 Y:1999 | 05 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,660 | $530 | Implemented |
CO0443 # 06 Y:1999 | 06 | 1999 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,210 | $1,000 | Implemented |
CO0443 # 07 Y:1999 | 07 | 1999 | BURN WASTE OIL FOR HEAT | $17,150 | $10,500 | Not Implemented |
CO0443 # 08 Y:1999 | 08 | 1999 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $31,200 | $8,000 | Implemented |
CO0439 # 01 Y:1999 | 01 | 1999 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $187,200 | $13,080 | Implemented |
CO0439 # 02 Y:1999 | 02 | 1999 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $102,440 | $400,000 | Not Implemented |
CO0439 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,900 | $2,000 | Implemented |
CO0439 # 04 Y:1999 | 04 | 1999 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,620 | $8,400 | Implemented |
CO0418 # 01 Y:1998 | 01 | 1998 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,020 | $2,000 | Implemented |