Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
345
matching recommendationsSIC | 353 | Construction And Related Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0649 # 05 Y:2002 | 05 | 2002 | $397,966 | $600,000 | Not Implemented | |
OK0624 # 01 Y:2001 | 01 | 2001 | AIR CONDITION ONLY SPACE NECESSARY | $2,978 | $130 | Not Implemented |
OK0624 # 02 Y:2001 | 02 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $4,484 | $255 | Implemented |
OK0624 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,627 | $240 | Implemented |
OK0624 # 04 Y:2001 | 04 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,170 | $50,000 | Not Implemented |
OK0624 # 05 Y:2001 | 05 | 2001 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $131,000 | $92,000 | Implemented |
OK0624 # 06 Y:2001 | 06 | 2001 | INSTALL EQUIPMENT TO MOVE PRODUCT | $200,000 | $200,000 | Not Implemented |
OK0612 # 01 Y:2001 | 01 | 2001 | INSTALL SET-BACK TIMERS | $88,000 | $17,542 | Implemented |
OK0612 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,333 | $577 | Not Implemented |
OK0612 # 03 Y:2001 | 03 | 2001 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $2,772 | $5,200 | Not Implemented |
OK0612 # 04 Y:2001 | 04 | 2001 | PAY BILLS ON TIME TO AVOID LATE FEES | $463 | $0 | Implemented |
OK0612 # 05 Y:2001 | 05 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $1,650 | $720 | Implemented |
OK0612 # 06 Y:2001 | 06 | 2001 | OPTIMIZE PLANT POWER FACTOR | $14,115 | $5,150 | Not Implemented |
OK0574 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,785 | $300 | Implemented |
OK0574 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,381 | $2,100 | Implemented |
OK0574 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $934 | $1,524 | Not Implemented |
OK0574 # 04 Y:1999 | 04 | 1999 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $129,375 | $0 | Implemented |
OK0574 # 05 Y:1999 | 05 | 1999 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $6,000 | $0 | Not Implemented |
OK0574 # 06 Y:1999 | 06 | 1999 | BURN WASTE OIL FOR HEAT | $6,148 | $10,470 | Not Implemented |
OK0573 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,582 | $16,945 | Not Implemented |
OK0573 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,215 | $45,737 | Not Implemented |
OK0573 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,266 | $1,900 | Implemented |
OK0573 # 04 Y:1999 | 04 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $545 | $246 | Not Implemented |
OK0573 # 05 Y:1999 | 05 | 1999 | RECOVER AND REUSE WASTE MATERIAL | $13,831 | $8,000 | Not Implemented |
OK0573 # 06 Y:1999 | 06 | 1999 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $6,895 | $34,750 | Implemented |