Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,933
matching recommendationsSIC | 354 | Metalworking Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0375 # 01 Y:2008 | 01 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,790 | $7,000 | Not Implemented |
NC0375 # 02 Y:2008 | 02 | 2008 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $15,885 | $41,750 | Not Implemented |
NC0375 # 03 Y:2008 | 03 | 2008 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,903 | $7,500 | Implemented |
NC0375 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,473 | $1,680 | Implemented |
NC0375 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,999 | $4,820 | Implemented |
NC0375 # 06 Y:2008 | 06 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $1,686 | $2,173 | Implemented |
WV0374 # 01 Y:2008 | 01 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $25,144 | $12,730 | Implemented |
WV0374 # 02 Y:2008 | 02 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $15,831 | $2,213 | Implemented |
WV0374 # 03 Y:2008 | 03 | 2008 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $7,994 | $4,500 | Implemented |
WV0374 # 04 Y:2008 | 04 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $7,339 | $1,076 | Implemented |
WV0374 # 05 Y:2008 | 05 | 2008 | OPTIMIZE PLANT POWER FACTOR | $5,562 | $11,346 | Not Implemented |
WV0374 # 06 Y:2008 | 06 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,079 | $6,378 | Implemented |
WV0374 # 07 Y:2008 | 07 | 2008 | INSTALL OCCUPANCY SENSORS | $4,440 | $612 | Not Implemented |
WV0374 # 08 Y:2008 | 08 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,513 | $315 | Implemented |
WV0374 # 09 Y:2008 | 09 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,039 | $9,054 | Not Implemented |
WV0374 # 10 Y:2008 | 10 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,784 | $440 | Not Implemented |
WV0374 # 11 Y:2008 | 11 | 2008 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,750 | $1,884 | Not Implemented |
WV0374 # 12 Y:2008 | 12 | 2008 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $389 | $690 | Not Implemented |
WV0373 # 07 Y:2008 | 07 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $647 | $106 | Not Implemented |
WV0373 # 08 Y:2008 | 08 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $581 | $336 | Implemented |
WV0373 # 09 Y:2008 | 09 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $384 | $762 | Not Implemented |
WV0373 # 10 Y:2008 | 10 | 2008 | USE SYNTHETIC LUBRICANT | $75 | $21 | Not Implemented |
WV0373 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,505 | $23,741 | Not Implemented |
WV0373 # 02 Y:2008 | 02 | 2008 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $13,342 | $29,120 | Not Implemented |
WV0373 # 03 Y:2008 | 03 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,596 | $273 | Not Implemented |