Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,933
matching recommendationsSIC | 354 | Metalworking Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OD0093 # 02 Y:1997 | 02 | 1997 | UPGRADE CONTROLS ON COMPRESSORS | $322 | $560 | Implemented |
OD0093 # 03 Y:1997 | 03 | 1997 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $1,164 | $3,797 | Not Implemented |
OD0093 # 04 Y:1997 | 04 | 1997 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $2,500 | $0 | Not Implemented |
UM0095 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,423 | $1,650 | Implemented |
UM0095 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,152 | $10,210 | Not Implemented |
UM0095 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $373 | $600 | Implemented |
UM0095 # 04 Y:1997 | 04 | 1997 | INSTALL OCCUPANCY SENSORS | $688 | $400 | Not Implemented |
UM0095 # 05 Y:1997 | 05 | 1997 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $3,511 | $3,500 | Implemented |
UM0095 # 06 Y:1997 | 06 | 1997 | EXPAND OPERATIONS INTO UNUSED SPACE | $6,800 | $400 | Implemented |
UM0089 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $881 | $1,000 | Not Implemented |
UM0089 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,465 | $25,326 | Not Implemented |
UM0089 # 03 Y:1997 | 03 | 1997 | INSTALL OCCUPANCY SENSORS | $1,588 | $1,000 | Not Implemented |
UM0089 # 04 Y:1997 | 04 | 1997 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $224 | $0 | Not Implemented |
UM0089 # 05 Y:1997 | 05 | 1997 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $12,931 | $6,343 | Not Implemented |
TN0609 # 01 Y:1997 | 01 | 1997 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $83,060 | $19,080 | Not Implemented |
TN0609 # 02 Y:1997 | 02 | 1997 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $64,970 | $45,880 | Not Implemented |
TN0609 # 03 Y:1997 | 03 | 1997 | ALLOW DRAINAGE BEFORE WITHDRAWING OBJECT | $10,970 | $5,080 | Not Implemented |
TN0609 # 04 Y:1997 | 04 | 1997 | USE EVAPORATION TO CONCENTRATE MATERIAL | $8,030 | $20,880 | Not Implemented |
TN0609 # 05 Y:1997 | 05 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $5,330 | $6,200 | Implemented |
TN0609 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $860 | $600 | Not Implemented |
SD0161 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $24,903 | $21,360 | Implemented |
SD0161 # 02 Y:1997 | 02 | 1997 | REPLACE BOILER | $38,307 | $8,000 | Not Implemented |
SD0161 # 03 Y:1997 | 03 | 1997 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $14,372 | $0 | Implemented |
SD0161 # 04 Y:1997 | 04 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,046 | $4,000 | Implemented |
SD0161 # 05 Y:1997 | 05 | 1997 | USE OPTIMUM THICKNESS INSULATION | $3,460 | $108 | Implemented |