Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
328
matching recommendationsSIC | 3564 | Blowers And Fans |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0302 # 08 Y:1997 | 08 | 1997 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $210 | $0 | Implemented |
IA0166 # 02 Y:1997 | 02 | 1997 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $31,899 | $4,200 | Implemented |
IA0166 # 03 Y:1997 | 03 | 1997 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $9,799 | $200 | Implemented |
IA0166 # 05 Y:1997 | 05 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,401 | $444 | Implemented |
IA0166 # 06 Y:1997 | 06 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $318 | $908 | Implemented |
IA0166 # 07 Y:1997 | 07 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,127 | $1,532 | Implemented |
IA0166 # 08 Y:1997 | 08 | 1997 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $1,281 | $0 | Implemented |
IA0166 # 09 Y:1997 | 09 | 1997 | OPTIMIZE PLANT POWER FACTOR | $1,096 | $4,700 | Implemented |
IA0166 # 10 Y:1997 | 10 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $948 | $3,374 | Implemented |
TN0604 # 01 Y:1997 | 01 | 1997 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $36,000 | $0 | Implemented |
TN0604 # 02 Y:1997 | 02 | 1997 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $28,880 | $7,540 | Implemented |
TN0604 # 06 Y:1997 | 06 | 1997 | USE SYNTHETIC LUBRICANT | $432 | $0 | Implemented |
AR0106 # 01 Y:1997 | 01 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,654 | $690 | Implemented |
AR0106 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,804 | $1,415 | Implemented |
AR0106 # 03 Y:1997 | 03 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $856 | $0 | Implemented |
AR0106 # 05 Y:1997 | 05 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,578 | $350 | Implemented |
AR0106 # 08 Y:1997 | 08 | 1997 | MINIMIZE WATER USAGE | $616 | $100 | Implemented |
UF0164 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,265 | $3,303 | Implemented |
UF0164 # 04 Y:1996 | 04 | 1996 | MOVE BOILER TO MORE EFFICIENT LOCATION | $10,185 | $0 | Implemented |
UF0164 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,142 | $600 | Implemented |
UF0164 # 07 Y:1996 | 07 | 1996 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $3,240 | $0 | Implemented |
WV0076 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,723 | $2,483 | Implemented |
WV0076 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,292 | $3,720 | Implemented |
WV0076 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $494 | $400 | Implemented |
WV0076 # 04 Y:1996 | 04 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,347 | $35 | Implemented |