Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsSIC | 3578 | Calculating And Accounting Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0941 # 03 Y:2016 | 03 | 2016 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,497 | $1,960 | Implemented |
OK0941 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,762 | $25,920 | Implemented |
SU0381 # 06 Y:2015 | 06 | 2015 | UPGRADE OBSOLETE EQUIPMENT | $446 | $958 | Implemented |
SU0381 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $452 | $211 | Implemented |
SU0381 # 03 Y:2015 | 03 | 2015 | USE SYNTHETIC LUBRICANT | $1,717 | $0 | Implemented |
SU0381 # 01 Y:2015 | 01 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,133 | $0 | Implemented |
SU0381 # 08 Y:2015 | 08 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,394 | $50,904 | Implemented |
SU0324 # 07 Y:2012 | 07 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,282 | $6,008 | Implemented |
SU0324 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $820 | $280 | Implemented |
SU0324 # 03 Y:2012 | 03 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $952 | $0 | Implemented |
SU0324 # 02 Y:2012 | 02 | 2012 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,326 | $0 | Implemented |
SU0324 # 01 Y:2012 | 01 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,908 | $0 | Implemented |
IA0443 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,968 | $3,879 | Implemented |
IA0443 # 11 Y:2009 | 11 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $377 | $65 | Implemented |
IA0443 # 08 Y:2009 | 08 | 2009 | OPTIMIZE PLANT POWER FACTOR | $4,398 | $4,659 | Implemented |
IA0443 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,745 | $256 | Implemented |
IA0443 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,934 | $20,207 | Implemented |
SU0274 # 04 Y:2009 | 04 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $498 | $0 | Implemented |
SU0274 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,346 | $400 | Implemented |
SU0274 # 06 Y:2009 | 06 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $316 | $204 | Implemented |
SU0274 # 11 Y:2009 | 11 | 2009 | OPTIMIZE PLANT POWER FACTOR | $1,192 | $7,749 | Implemented |
SU0274 # 03 Y:2009 | 03 | 2009 | USE SYNTHETIC LUBRICANT | $545 | $0 | Implemented |
OK0207 # 04 Y:1986 | 04 | 1986 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,124 | $8,200 | Implemented |
OK0207 # 03 Y:1986 | 03 | 1986 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $24 | $4 | Implemented |
OK0207 # 02 Y:1986 | 02 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $153 | $87 | Implemented |