IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

67

matching recommendations
Reset
SIC 358 Refrigeration And Service Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0800 # 03 Y:2010 03 2010 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $209 $334 Implemented
OK0800 # 02 Y:2010 02 2010 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $4,667 $2,700 Implemented
OK0800 # 04 Y:2010 04 2010 INSTALL OCCUPANCY SENSORS $860 $1,865 Implemented
OK0800 # 05 Y:2010 05 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,134 $706 Implemented
OK0800 # 06 Y:2010 06 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,134 $1,678 Implemented
OK0796 # 02 Y:2010 02 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,028 $14,578 Implemented
OK0796 # 05 Y:2010 05 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,383 $500 Implemented
OK0796 # 03 Y:2010 03 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,129 $5,526 Implemented
OK0796 # 08 Y:2010 08 2010 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $786 $1,850 Implemented
OK0689 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,433 $252 Implemented
OK0689 # 03 Y:2004 03 2004 INSTALL OCCUPANCY SENSORS $1,079 $2,156 Implemented
OK0661 # 09 Y:2003 09 2003 $11,440 $2,500 Implemented
OK0661 # 08 Y:2003 08 2003 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $13,061 $45,000 Implemented
OK0661 # 04 Y:2003 04 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,319 $823 Implemented
OK0661 # 02 Y:2003 02 2003 $20,400 $0 Implemented
OK0614 # 03 Y:2001 03 2001 INSULATE BARE EQUIPMENT $5,656 $9,700 Implemented
OK0614 # 05 Y:2001 05 2001 $9,100 $4,000 Implemented
OK0512 # 05 Y:1996 05 1996 INSTALL OCCUPANCY SENSORS $497 $528 Implemented
OK0512 # 04 Y:1996 04 1996 INSTALL TIMERS AND/OR THERMOSTATS $689 $620 Implemented
OK0512 # 06 Y:1996 06 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $106 $494 Implemented
OK0512 # 07 Y:1996 07 1996 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $500 $0 Implemented
OK0512 # 03 Y:1996 03 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $819 $0 Implemented
OK0512 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,028 $16,512 Implemented
OK0470 # 02 Y:1995 02 1995 UPGRADE OBSOLETE EQUIPMENT $749 $2,050 Implemented
OK0470 # 06 Y:1995 06 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $119 $395 Implemented