Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,249
matching recommendationsSIC | 359 | Industrial Machinery, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0176 # 04 Y:2017 | 04 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,930 | $2,190 | Not Implemented |
DL0176 # 05 Y:2017 | 05 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,415 | $16,875 | Not Implemented |
DL0176 # 06 Y:2017 | 06 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,410 | $4,465 | Implemented |
DL0176 # 07 Y:2017 | 07 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,798 | $4,484 | Implemented |
DL0176 # 08 Y:2017 | 08 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,869 | $2,965 | Implemented |
DL0176 # 09 Y:2017 | 09 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $880 | $800 | Not Implemented |
DL0176 # 10 Y:2017 | 10 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $5,330 | $6,700 | Not Implemented |
UF0506 # 01 Y:2017 | 01 | 2017 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,263 | $5,454 | Not Implemented |
UF0506 # 02 Y:2017 | 02 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,519 | $1,169 | Implemented |
UF0506 # 03 Y:2017 | 03 | 2017 | INSTALL COMMON HEADER ON COMPRESSORS | $4,067 | $3,216 | Not Implemented |
UF0506 # 04 Y:2017 | 04 | 2017 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,070 | $1,171 | Not Implemented |
UF0506 # 05 Y:2017 | 05 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,010 | $6,500 | Not Implemented |
UF0506 # 06 Y:2017 | 06 | 2017 | INSTALL SET-BACK TIMERS | $1,014 | $667 | Implemented |
UF0506 # 07 Y:2017 | 07 | 2017 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $60,000 | $55,338 | Not Implemented |
SF0499 # 01 Y:2017 | 01 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,800 | $0 | Implemented |
SF0499 # 02 Y:2017 | 02 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,955 | $0 | Implemented |
SF0499 # 03 Y:2017 | 03 | 2017 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $600 | $0 | Not Implemented |
SF0499 # 04 Y:2017 | 04 | 2017 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $18,778 | $30,000 | Implemented |
SF0499 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,191 | $12,954 | Implemented |
SF0499 # 06 Y:2017 | 06 | 2017 | USE SOLAR HEAT TO MAKE ELECTRICTY | $77,403 | $434,700 | Implemented |
SU0436 # 01 Y:2017 | 01 | 2017 | DISCONNECT BALLASTS | $95 | $0 | Implemented |
SU0436 # 02 Y:2017 | 02 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,538 | $388 | Not Implemented |
SU0436 # 03 Y:2017 | 03 | 2017 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $3,447 | $2,277 | Implemented |
SU0436 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $800 | $741 | Implemented |
SU0436 # 05 Y:2017 | 05 | 2017 | ELIMINATE/REDUCE AN OPERATION | $4,066 | $4,830 | Implemented |