Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
65
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0801 # 01 Y:2009 | 01 | 2009 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $18,742 | $14,833 | Implemented |
UD0801 # 02 Y:2009 | 02 | 2009 | REDUCE VENTILATION AIR | $10,610 | $14,833 | Implemented |
UD0801 # 03 Y:2009 | 03 | 2009 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $4,599 | $14,833 | Implemented |
UD0801 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,877 | $16,721 | Implemented |
UD0801 # 05 Y:2009 | 05 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,100 | $14,833 | Implemented |
UD0801 # 07 Y:2009 | 07 | 2009 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $993 | $45,000 | Implemented |
MA0651 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,340 | $96,800 | Implemented |
MA0651 # 03 Y:2009 | 03 | 2009 | REPLACE BOILER | $10,080 | $30,700 | Implemented |
AM0559 # 03 Y:2009 | 03 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,800 | $15 | Implemented |
AM0559 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $79,100 | $225,000 | Implemented |
AM0559 # 06 Y:2009 | 06 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,245 | $500 | Implemented |
AM0559 # 05 Y:2009 | 05 | 2009 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,810 | $500 | Implemented |
AM0559 # 04 Y:2009 | 04 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,700 | $0 | Implemented |
SD0415 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,503 | $18,750 | Implemented |
SD0415 # 03 Y:2009 | 03 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,009 | $0 | Implemented |
SD0415 # 05 Y:2009 | 05 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,035 | $128 | Implemented |
SD0415 # 06 Y:2009 | 06 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $910 | $1,000 | Implemented |
SD0415 # 09 Y:2009 | 09 | 2009 | INSTALL OCCUPANCY SENSORS | $154 | $347 | Implemented |
TT0034 # 08 Y:2009 | 08 | 2009 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $2,400 | $0 | Implemented |
TT0034 # 04 Y:2009 | 04 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,900 | $800 | Implemented |
TT0034 # 07 Y:2009 | 07 | 2009 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $4,000 | $0 | Implemented |
AM0556 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,000 | $36,100 | Implemented |
AM0556 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,800 | $1,000 | Implemented |
AM0556 # 05 Y:2009 | 05 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,650 | $11,713 | Implemented |
AM0556 # 08 Y:2009 | 08 | 2009 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,290 | $1,000 | Implemented |