Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
285
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0181 # 03 Y:2000 | 03 | 2000 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $18,564 | $37,378 | Not Implemented |
NC0181 # 04 Y:2000 | 04 | 2000 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $5,692 | $18,000 | Not Implemented |
NC0181 # 05 Y:2000 | 05 | 2000 | AIR CONDITION ONLY SPACE NECESSARY | $14,765 | $42,000 | Not Implemented |
NC0165 # 01 Y:1999 | 01 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $28,720 | $10,000 | Implemented |
NC0165 # 02 Y:1999 | 02 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,539 | $1,500 | Implemented |
NC0165 # 03 Y:1999 | 03 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $151,290 | $29,000 | Implemented |
NC0165 # 04 Y:1999 | 04 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $231,300 | $1,600,000 | Not Implemented |
NC0165 # 05 Y:1999 | 05 | 1999 | INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT | $824,740 | $836,000 | Implemented |
NC0157 # 01 Y:1999 | 01 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,968 | $1,500 | Not Implemented |
NC0157 # 02 Y:1999 | 02 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,307 | $240 | Not Implemented |
NC0157 # 03 Y:1999 | 03 | 1999 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $6,654 | $2,000 | Not Implemented |
NC0157 # 04 Y:1999 | 04 | 1999 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $98,761 | $465,000 | Not Implemented |
NC0157 # 05 Y:1999 | 05 | 1999 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $17,776 | $20,000 | Not Implemented |
NC0157 # 06 Y:1999 | 06 | 1999 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,015 | $3,000 | Implemented |
NC0157 # 07 Y:1999 | 07 | 1999 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $8,000 | $200 | Implemented |
NC0157 # 08 Y:1999 | 08 | 1999 | ADD ADDITIONAL PRODUCTION SHIFT | $100,000 | $1,000 | Not Implemented |
NC0157 # 09 Y:1999 | 09 | 1999 | MODIFY STARTUP/SHUTDOWN TIMES | $3,193 | $0 | Implemented |
NC0152 # 01 Y:1998 | 01 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,388 | $1,000 | Not Implemented |
NC0152 # 02 Y:1998 | 02 | 1998 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,988 | $13,000 | Not Implemented |
NC0152 # 03 Y:1998 | 03 | 1998 | COVER OPEN TANKS | $1,006 | $100 | Implemented |
NC0152 # 04 Y:1998 | 04 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $396 | $80 | Not Implemented |
NC0152 # 05 Y:1998 | 05 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,160 | $0 | Implemented |
NC0152 # 06 Y:1998 | 06 | 1998 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $3,010 | $5,000 | Not Implemented |
NC0152 # 07 Y:1998 | 07 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $563 | $200 | Implemented |
NC0152 # 08 Y:1998 | 08 | 1998 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $16,777 | $4,000 | Not Implemented |