Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,242

matching recommendations
Reset
SIC 364 Electric Lighting And Wiring Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0090 # 01 Y:1997 01 1997 INSTALL TIMERS AND/OR THERMOSTATS $4,329 $5,125 Implemented
MS0090 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,624 $8,079 Implemented
MS0090 # 03 Y:1997 03 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $292 $577 Not Implemented
MS0090 # 04 Y:1997 04 1997 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,931 $2,350 Not Implemented
MS0090 # 05 Y:1997 05 1997 RECOVER AND REUSE COOLING WATER $37,143 $7,666 Not Implemented
MS0090 # 06 Y:1997 06 1997 BURN WASTE OIL FOR HEAT $958 $1,995 Not Implemented
MS0090 # 07 Y:1997 07 1997 EXPAND OPERATIONS INTO UNUSED SPACE $5,005 $672 Implemented
MS0090 # 08 Y:1997 08 1997 INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE $1,657 $1,256 Implemented
WI0290 # 01 Y:1997 01 1997 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $119,620 $15,000 Implemented
WI0290 # 02 Y:1997 02 1997 REDUCE VENTILATION AIR $10,493 $15,000 Not Implemented
WI0290 # 03 Y:1997 03 1997 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $7,560 $5,000 Implemented
WI0290 # 04 Y:1997 04 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $10,200 $15,000 Not Implemented
WI0290 # 05 Y:1997 05 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,755 $330 Implemented
WI0290 # 06 Y:1997 06 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,526 $1,380 Not Implemented
WI0290 # 07 Y:1997 07 1997 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $7,982 $0 Not Implemented
WI0290 # 08 Y:1997 08 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,333 $500 Implemented
WI0290 # 09 Y:1997 09 1997 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,280 $1,120 Implemented
WI0290 # 10 Y:1997 10 1997 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES $784 $0 Not Implemented
AR0103 # 01 Y:1996 01 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,369 $20 Implemented
AR0103 # 02 Y:1996 02 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,617 $450 Implemented
AR0103 # 03 Y:1996 03 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,695 $5,860 Implemented
AR0103 # 04 Y:1996 04 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $386 $0 Implemented
AR0103 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $872 $624 Not Implemented
AR0103 # 06 Y:1996 06 1996 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,326 $2,326 Not Implemented
AR0103 # 07 Y:1996 07 1996 MAINTAIN MACHINES TO REDUCE LEAKS $900 $300 Implemented