Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,411
matching recommendationsSIC | 367 | Electronic Components And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0344 # 04 Y:2006 | 04 | 2006 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $22,182 | $27,387 | Implemented |
WV0344 # 05 Y:2006 | 05 | 2006 | OPTIMIZE PLANT POWER FACTOR | $18,000 | $32,500 | Implemented |
WV0344 # 06 Y:2006 | 06 | 2006 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $16,147 | $26,662 | Implemented |
WV0344 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,355 | $12,137 | Implemented |
WV0344 # 09 Y:2006 | 09 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,629 | $0 | Implemented |
WV0344 # 10 Y:2006 | 10 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,177 | $1,896 | Implemented |
WV0344 # 11 Y:2006 | 11 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,355 | $436 | Implemented |
WV0344 # 13 Y:2006 | 13 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,197 | $1,811 | Implemented |
AM0515 # 03 Y:2006 | 03 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $66,000 | $65,000 | Implemented |
AM0515 # 06 Y:2006 | 06 | 2006 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $16,500 | $6,700 | Implemented |
AM0515 # 07 Y:2006 | 07 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,580 | $27,400 | Implemented |
AM0515 # 08 Y:2006 | 08 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $6,900 | $80 | Implemented |
AM0515 # 10 Y:2006 | 10 | 2006 | INSTALL OCCUPANCY SENSORS | $4,440 | $1,580 | Implemented |
LM0119 # 06 Y:2006 | 06 | 2006 | CONDENSE OPERATION INTO ONE BUILDING | $3,375,000 | $500,000 | Implemented |
AM0514 # 01 Y:2006 | 01 | 2006 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $189,400 | $50,000 | Implemented |
AM0514 # 03 Y:2006 | 03 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,900 | $500 | Implemented |
AM0514 # 04 Y:2006 | 04 | 2006 | INSTALL OCCUPANCY SENSORS | $2,520 | $790 | Implemented |
AM0514 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,305 | $1,450 | Implemented |
WI0514 # 02 Y:2006 | 02 | 2006 | IMPROVE SPACE COMFORT CONDITIONING | $9,074 | $900 | Implemented |
WI0514 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,466 | $6,300 | Implemented |
WI0514 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,678 | $0 | Implemented |
LE0228 # 02 Y:2006 | 02 | 2006 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $4,308 | $620 | Implemented |
LE0228 # 03 Y:2006 | 03 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $3,963 | $1,250 | Implemented |
LE0228 # 04 Y:2006 | 04 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,427 | $2,500 | Implemented |
LE0228 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,503 | $100 | Implemented |