Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
100
matching recommendationsSIC | 3679 | Electronic Components, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0182 # 05 Y:1996 | 05 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $19,328 | $21,600 | Not Implemented |
AS0182 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $11,259 | $9,718 | Not Implemented |
AS0182 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,593 | $500 | Not Implemented |
AS0182 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,782 | $430 | Implemented |
AS0182 # 11 Y:1996 | 11 | 1996 | MINIMIZE WATER USAGE | $5,511 | $5,000 | Not Implemented |
AS0182 # 01 Y:1996 | 01 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,232 | $0 | Not Implemented |
TN0590 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,325 | $260 | Not Implemented |
TN0590 # 03 Y:1996 | 03 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,321 | $8,150 | Implemented |
TN0590 # 01 Y:1996 | 01 | 1996 | USE PLASTIC PALLETS INSTEAD OF WOOD | $162,200 | $297,300 | Implemented |
TN0590 # 02 Y:1996 | 02 | 1996 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,400 | $0 | Implemented |
TN0590 # 05 Y:1996 | 05 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $640 | $1,120 | Implemented |
KG0065 # 01 Y:1996 | 01 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,183 | $8,000 | Not Implemented |
KG0065 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,588 | $906 | Not Implemented |
KG0065 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,200 | $3,480 | Not Implemented |
KG0065 # 04 Y:1996 | 04 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $732 | $300 | Not Implemented |
KG0065 # 05 Y:1996 | 05 | 1996 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $427 | $400 | Not Implemented |
KG0065 # 06 Y:1996 | 06 | 1996 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $5,889 | $3,200 | Not Implemented |
MA0368 # 02 Y:1996 | 02 | 1996 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $8,710 | $25,500 | Not Implemented |
MA0368 # 01 Y:1996 | 01 | 1996 | TREAT AND REUSE RINSE WATERS | $17,190 | $12,000 | Not Implemented |
MA0368 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,509 | $11,189 | Implemented |
MA0368 # 04 Y:1996 | 04 | 1996 | REPAIR OR REPLACE STEAM TRAPS | $1,990 | $868 | Implemented |
AS0177 # 08 Y:1996 | 08 | 1996 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,920 | $0 | Not Implemented |
AS0177 # 07 Y:1996 | 07 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,289 | $8,800 | Not Implemented |
AS0177 # 06 Y:1996 | 06 | 1996 | INSULATE BARE EQUIPMENT | $444 | $180 | Implemented |
AS0177 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $204 | $390 | Not Implemented |