Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

134

matching recommendations
Reset
SIC 37 Transportation Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0512 # 02 Y:2006 02 2006 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $32,700 $20,600 Not Implemented
OR0512 # 03 Y:2006 03 2006 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $7,000 $5,000 Implemented
OR0512 # 04 Y:2006 04 2006 RECOVER WASTE HEAT FROM EQUIPMENT $6,300 $5,000 Implemented
OR0512 # 05 Y:2006 05 2006 UPGRADE CONTROLS ON COMPRESSORS $4,400 $7,500 Implemented
OR0396 # 01 Y:2001 01 2001 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $164,000 $5,000 Implemented
OR0396 # 02 Y:2001 02 2001 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $167,300 $38,000 Implemented
OR0396 # 03 Y:2001 03 2001 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $42,223 $5,000 Not Implemented
OR0396 # 04 Y:2001 04 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $13,160 $7,740 Implemented
OR0396 # 05 Y:2001 05 2001 INSTALL OCCUPANCY SENSORS $657 $1,995 Implemented
OR0390 # 01 Y:2001 01 2001 PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST $79,800 $30,700 Implemented
OR0390 # 02 Y:2001 02 2001 OPTIMIZE PLANT POWER FACTOR $2,467 $2,100 Not Implemented
OR0390 # 03 Y:2001 03 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,749 $1,700 Implemented
OR0390 # 04 Y:2001 04 2001 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $3,277 $2,100 Implemented
OR0390 # 05 Y:2001 05 2001 COMBINE UTILITY METERS $1,062 $3,925 Not Implemented
OR0314 # 01 Y:1998 01 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $9,110 $0 Implemented
OR0314 # 02 Y:1998 02 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,164 $4,524 Implemented
OR0314 # 03 Y:1998 03 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,150 $5,034 Implemented
OR0314 # 04 Y:1998 04 1998 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,645 $500 Implemented
OR0314 # 05 Y:1998 05 1998 BURN A LESS EXPENSIVE GRADE OF FUEL $1,200 $10,000 Not Implemented
OR0314 # 06 Y:1998 06 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,787 $2,000 Implemented
OR0314 # 07 Y:1998 07 1998 INSTALL EFFICIENT RECTIFIERS $1,220 $7,900 Not Implemented
OR0314 # 08 Y:1998 08 1998 UPGRADE CONTROLS ON COMPRESSORS $4,685 $3,280 Implemented
OR0314 # 09 Y:1998 09 1998 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $9,562 $6,000 Not Implemented
OR0259 # 01 Y:1996 01 1996 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS $7,505 $0 Implemented
OR0259 # 02 Y:1996 02 1996 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $584 $0 Implemented