Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
779
matching recommendationsSIC | 382 | Measuring And Controlling Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DS0174 # 04 Y:2000 | 04 | 2000 | AUTOMATE FINISHING PROCESS | $45,038 | $6,995 | Implemented |
DS0174 # 05 Y:2000 | 05 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $365 | $0 | Implemented |
NC0194 # 01 Y:2000 | 01 | 2000 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $429 | $835 | Implemented |
NC0194 # 02 Y:2000 | 02 | 2000 | INSTALL SKYLIGHTS | $3,443 | $7,000 | Implemented |
NC0194 # 03 Y:2000 | 03 | 2000 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $13,561 | $29,000 | Implemented |
NC0194 # 05 Y:2000 | 05 | 2000 | RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER | $29,846 | $20,200 | Implemented |
CO0466 # 01 Y:2000 | 01 | 2000 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,420 | $10,000 | Implemented |
CO0466 # 04 Y:2000 | 04 | 2000 | INSTALL OCCUPANCY SENSORS | $470 | $1,000 | Implemented |
CO0466 # 06 Y:2000 | 06 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $640 | $0 | Implemented |
CO0466 # 07 Y:2000 | 07 | 2000 | MINIMIZE WATER USAGE | $1,030 | $320 | Implemented |
CO0466 # 08 Y:2000 | 08 | 2000 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $50,740 | $40,000 | Implemented |
MA0446 # 03 Y:1999 | 03 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $14,463 | $20,800 | Implemented |
MA0446 # 04 Y:1999 | 04 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,237 | $3,575 | Implemented |
MA0446 # 06 Y:1999 | 06 | 1999 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $2,849 | $0 | Implemented |
MA0446 # 07 Y:1999 | 07 | 1999 | AIR CONDITION ONLY SPACE NECESSARY | $1,137 | $2,670 | Implemented |
MA0446 # 10 Y:1999 | 10 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $638 | $300 | Implemented |
WI0359 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,815 | $100 | Implemented |
WI0359 # 06 Y:1999 | 06 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,781 | $0 | Implemented |
WI0359 # 09 Y:1999 | 09 | 1999 | REDUCE VENTILATION AIR | $648 | $500 | Implemented |
WI0359 # 10 Y:1999 | 10 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $278 | $0 | Implemented |
SD0228 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,410 | $6,484 | Implemented |
SD0228 # 05 Y:1999 | 05 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $793 | $0 | Implemented |
UD0568 # 03 Y:1999 | 03 | 1999 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $5,171 | $4,000 | Implemented |
MA0434 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $230 | $130 | Implemented |
MA0434 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $71 | $50 | Implemented |