Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,571

matching recommendations
Reset
ARC 2 ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0734 # 05 Y:2016 05 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $31,330 $46,120 n/a
WV0536 # 08 Y:2016 08 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $394 $60 Not Implemented
WV0536 # 07 Y:2016 07 2016 PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT $735 $4,320 Implemented
WV0536 # 06 Y:2016 06 2016 DEVELOP A REPAIR/REPLACE POLICY $1,406 $617 Implemented
WV0536 # 05 Y:2016 05 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,808 $2,250 Implemented
WV0536 # 04 Y:2016 04 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,983 $2,015 Implemented
WV0536 # 03 Y:2016 03 2016 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $3,788 $1,000 Implemented
WV0536 # 02 Y:2016 02 2016 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS $8,800 $31,000 Not Implemented
WV0536 # 01 Y:2016 01 2016 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $10,902 $82,500 Not Implemented
LE0424 # 01 Y:2016 01 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,742 $1,000 Implemented
LE0424 # 02 Y:2016 02 2016 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,378 $600 Implemented
LE0424 # 03 Y:2016 03 2016 RECOVER WASTE HEAT FROM EQUIPMENT $7,795 $2,750 Implemented
LE0424 # 04 Y:2016 04 2016 INSTALL OCCUPANCY SENSORS $825 $500 Not Implemented
LE0424 # 05 Y:2016 05 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,065 $3,420 Implemented
LE0424 # 06 Y:2016 06 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $760 $3,440 Not Implemented
WM0095 # 01 Y:2016 01 2016 STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS $286,874 $438,150 Not Implemented
WM0095 # 03 Y:2016 03 2016 REPAIR AND ELIMINATE STEAM LEAKS $7,438 $1,560 Implemented
WM0095 # 04 Y:2016 04 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,649 $2,000 Implemented
WM0095 # 05 Y:2016 05 2016 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,197 $0 Not Implemented
WM0095 # 06 Y:2016 06 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,696 $7,212 Implemented
WM0095 # 07 Y:2016 07 2016 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,095 $735 Not Implemented
NC0576 # 01 Y:2016 01 2016 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $16,790 $3,000 Implemented
NC0576 # 02 Y:2016 02 2016 REPAIR OR REPLACE STEAM TRAPS $108,434 $80,000 Implemented
NC0576 # 03 Y:2016 03 2016 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $198,172 $1,100,000 Not Implemented
NC0576 # 04 Y:2016 04 2016 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $60,776 $250,000 Not Implemented