Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

516

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0393 # 05 Y:1993 05 1993 INSULATE BARE EQUIPMENT $574 $1,800 Not Implemented
GT0488 # 02 Y:1993 02 1993 INCREASE AMOUNT OF CONDENSATE RETURNED $2,700 $5,000 Not Implemented
CO0262 # 05 Y:1993 05 1993 INSULATE BARE EQUIPMENT $640 $240 Implemented
IA0048 # 06 Y:1993 06 1993 INSULATE BARE EQUIPMENT $25 $43 Implemented
OR0168 # 01 Y:1993 01 1993 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $2,253 $0 Implemented
OR0168 # 03 Y:1993 03 1993 HEAT WATER WITH EXHAUST HEAT $3,366 $500 Implemented
MA0263 # 02 Y:1993 02 1993 RECOVER WASTE HEAT FROM EQUIPMENT $838 $1,562 Implemented
GT0487 # 05 Y:1993 05 1993 RECOVER WASTE HEAT FROM EQUIPMENT $775 $850 Implemented
GT0487 # 09 Y:1993 09 1993 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $7,530 $1,000 Implemented
GT0487 # 10 Y:1993 10 1993 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $790 $0 Implemented
TN0485 # 01 Y:1993 01 1993 RECOVER WASTE HEAT FROM EQUIPMENT $3,219 $3,110 Not Implemented
TN0485 # 05 Y:1993 05 1993 INSULATE BARE EQUIPMENT $633 $627 Not Implemented
AM0173 # 04 Y:1993 04 1993 REPAIR AND ELIMINATE STEAM LEAKS $3,670 $600 Implemented
CO0261 # 06 Y:1993 06 1993 RECOVER WASTE HEAT FROM EQUIPMENT $770 $2,300 Not Implemented
OK0396 # 01 Y:1993 01 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,199 $8,100 Implemented
KU0392 # 05 Y:1993 05 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,137 $2,500 Not Implemented
AM0170 # 04 Y:1993 04 1993 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,490 $20,650 Not Implemented
AM0170 # 05 Y:1993 05 1993 INSULATE BARE EQUIPMENT $6,070 $3,520 Not Implemented
AM0170 # 10 Y:1993 10 1993 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $410 $400 Not Implemented
AM0171 # 02 Y:1993 02 1993 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $10,780 $10,160 Not Implemented
AM0171 # 05 Y:1993 05 1993 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,710 $10,160 Not Implemented
HO0036 # 02 Y:1993 02 1993 INSTALL / REPAIR INSULATION ON STEAM LINES $759 $338 Not Implemented
HO0035 # 04 Y:1993 04 1993 INSULATE BARE EQUIPMENT $130 $184 n/a
AS0077 # 02 Y:1993 02 1993 INSULATE BARE EQUIPMENT $10,939 $9,136 Implemented
AS0076 # 08 Y:1993 08 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $15,260 $18,920 Not Implemented