Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
463
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0037 # 07 Y:1985 | 07 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $13,893 | $27,500 | Not Implemented |
LT0036 # 06 Y:1985 | 06 | 1985 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $1,457 | $1,840 | Not Implemented |
LT0036 # 04 Y:1985 | 04 | 1985 | INSULATE BARE EQUIPMENT | $5,267 | $350 | Not Implemented |
LT0034 # 04 Y:1985 | 04 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,050 | $417 | Implemented |
LT0034 # 01 Y:1985 | 01 | 1985 | COVER OPEN TANKS | $3,245 | $1,440 | Implemented |
LT0027 # 03 Y:1985 | 03 | 1985 | REPAIR AND ELIMINATE STEAM LEAKS | $1,218 | $45 | Implemented |
LT0027 # 02 Y:1985 | 02 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $12,690 | $1,135 | Not Implemented |
LT0027 # 01 Y:1985 | 01 | 1985 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $76,200 | $15,600 | Implemented |
KU0178 # 17 Y:1985 | 17 | 1985 | INSULATE BARE EQUIPMENT | $192 | $75 | Not Implemented |
KU0178 # 10 Y:1985 | 10 | 1985 | INSULATE BARE EQUIPMENT | $698 | $1,500 | Not Implemented |
KU0178 # 07 Y:1985 | 07 | 1985 | INSULATE BARE EQUIPMENT | $2,651 | $1,952 | Implemented |
KU0173 # 03 Y:1985 | 03 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,053 | $1,000 | Not Implemented |
KU0172 # 04 Y:1985 | 04 | 1985 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $451 | $0 | Not Implemented |
KU0172 # 01 Y:1985 | 01 | 1985 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $93,600 | $40,000 | Not Implemented |
KU0171 # 08 Y:1985 | 08 | 1985 | TURN OFF STEAM TRACING DURING MILD WEATHER | $442 | $0 | Implemented |
KU0171 # 07 Y:1985 | 07 | 1985 | REPAIR OR REPLACE STEAM TRAPS | $427 | $400 | Implemented |
KU0171 # 05 Y:1985 | 05 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $171 | $400 | Not Implemented |
KU0171 # 03 Y:1985 | 03 | 1985 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $793 | $628 | Not Implemented |
KU0171 # 02 Y:1985 | 02 | 1985 | INCREASE AMOUNT OF CONDENSATE RETURNED | $2,304 | $1,000 | Implemented |
KU0170 # 16 Y:1985 | 16 | 1985 | INSULATE BARE EQUIPMENT | $1,000 | $591 | Implemented |
KU0170 # 14 Y:1985 | 14 | 1985 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,514 | $1,300 | Implemented |
KU0170 # 13 Y:1985 | 13 | 1985 | REPAIR AND ELIMINATE STEAM LEAKS | $1,835 | $300 | Not Implemented |
KU0170 # 12 Y:1985 | 12 | 1985 | INSULATE BARE EQUIPMENT | $2,018 | $800 | Not Implemented |
KU0170 # 08 Y:1985 | 08 | 1985 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $2,764 | $700 | Implemented |
KU0170 # 06 Y:1985 | 06 | 1985 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,746 | $1,000 | Implemented |