Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

19,995

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0377 # 03 Y:1989 03 1989 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $3,740 $15,000 Not Implemented
GT0377 # 05 Y:1989 05 1989 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $1,623 $2,035 Implemented
OK0279 # 03 Y:1989 03 1989 INSULATE BARE EQUIPMENT $2,236 $2,512 Not Implemented
OK0279 # 04 Y:1989 04 1989 INSULATE BARE EQUIPMENT $5,203 $2,516 Not Implemented
OK0279 # 05 Y:1989 05 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $15,708 $10,392 Not Implemented
OK0279 # 07 Y:1989 07 1989 REPAIR AND ELIMINATE STEAM LEAKS $22,796 $0 Implemented
OK0279 # 12 Y:1989 12 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $14,887 $7,200 Not Implemented
OK0280 # 03 Y:1989 03 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $6,280 $893 Implemented
RU0054 # 06 Y:1989 06 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,711 $8,300 Implemented
RU0054 # 07 Y:1989 07 1989 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $3,481 $9,000 Not Implemented
RU0055 # 02 Y:1989 02 1989 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC $80,513 $66,700 Not Implemented
RU0056 # 01 Y:1989 01 1989 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $5,773 $10,000 Implemented
OR0050 # 02 Y:1989 02 1989 INSULATE BARE EQUIPMENT $1,546 $378 Not Implemented
OR0050 # 04 Y:1989 04 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,554 $650 Not Implemented
OR0050 # 07 Y:1989 07 1989 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $244 $267 Not Implemented
OR0050 # 08 Y:1989 08 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $379 $300 Implemented
OR0051 # 02 Y:1989 02 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $2,926 $0 Implemented
OR0051 # 03 Y:1989 03 1989 USE MINIMUM STEAM OPERATING PRESSURE $458 $0 Implemented
OR0051 # 04 Y:1989 04 1989 INSTALL STEAM TRAP $23,375 $2,335 Implemented
OR0052 # 01 Y:1989 01 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $880 $0 Implemented
OR0052 # 03 Y:1989 03 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $6,550 $2,400 Implemented
OR0052 # 04 Y:1989 04 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $411 $320 Not Implemented
OR0052 # 06 Y:1989 06 1989 INSULATE BARE EQUIPMENT $375 $385 Not Implemented
OR0052 # 07 Y:1989 07 1989 REPAIR OR REPLACE STEAM TRAPS $8,216 $10,500 Implemented
MA0146 # 03 Y:1989 03 1989 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $2,380 $4,505 Not Implemented