Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,409

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0311 # 05 Y:1990 05 1990 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $47 $200 Implemented
AM0084 # 02 Y:1990 02 1990 RECOVER WASTE HEAT FROM EQUIPMENT $2,615 $2,600 Implemented
AM0086 # 03 Y:1990 03 1990 REPAIR AND ELIMINATE STEAM LEAKS $2,700 $800 Implemented
AM0086 # 09 Y:1990 09 1990 INSTALL / REPAIR INSULATION ON STEAM LINES $167 $275 Implemented
CO0176 # 02 Y:1990 02 1990 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,130 $11,740 Not Implemented
CO0177 # 01 Y:1990 01 1990 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $11,860 $15,260 Not Implemented
CO0178 # 04 Y:1990 04 1990 RECOVER WASTE HEAT FROM EQUIPMENT $2,050 $1,500 Implemented
MA0174 # 01 Y:1990 01 1990 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $388 $649 Not Implemented
MA0174 # 06 Y:1990 06 1990 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $24,108 $27,827 Not Implemented
MA0174 # 07 Y:1990 07 1990 RECOVER WASTE HEAT FROM EQUIPMENT $35,725 $19,518 Not Implemented
MA0176 # 05 Y:1990 05 1990 RECOVER WASTE HEAT FROM EQUIPMENT $2,776 $2,000 Not Implemented
GT0402 # 01 Y:1990 01 1990 REPAIR AND ELIMINATE STEAM LEAKS $5,300 $400 Not Implemented
GT0402 # 06 Y:1990 06 1990 COVER OPEN TANKS $16,700 $20,200 Not Implemented
GT0403 # 05 Y:1990 05 1990 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,610 $9,150 Not Implemented
GT0403 # 06 Y:1990 06 1990 REPAIR AND ELIMINATE STEAM LEAKS $5,760 $275 Implemented
GT0403 # 07 Y:1990 07 1990 INSTALL / REPAIR INSULATION ON STEAM LINES $7,876 $5,715 Not Implemented
GT0399 # 01 Y:1990 01 1990 INSULATE BARE EQUIPMENT $615 $285 Not Implemented
GT0399 # 02 Y:1990 02 1990 INCREASE AMOUNT OF CONDENSATE RETURNED $910 $300 Implemented
GT0399 # 06 Y:1990 06 1990 REPAIR AND ELIMINATE STEAM LEAKS $1,950 $50 Implemented
GT0400 # 06 Y:1990 06 1990 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $3,030 $500 Not Implemented
KU0307 # 05 Y:1990 05 1990 USE MINIMUM SAFE OVEN VENTILATION $4,979 $600 Implemented
OR0081 # 01 Y:1990 01 1990 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,762 $68,000 Implemented
OR0081 # 02 Y:1990 02 1990 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $3,741 $635 Implemented
OK0305 # 02 Y:1990 02 1990 INSULATE BARE EQUIPMENT $1,153 $836 Implemented
OK0307 # 02 Y:1990 02 1990 RECOVER WASTE HEAT FROM EQUIPMENT $2,963 $1,405 Implemented