Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

19,994

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0321 # 04 Y:1987 04 1987 RECOVER WASTE HEAT FROM EQUIPMENT $795 $300 Implemented
TN0321 # 09 Y:1987 09 1987 INSULATE BARE EQUIPMENT $885 $615 Implemented
RU0008 # 01 Y:1987 01 1987 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $1,791 $456 Implemented
RU0009 # 01 Y:1987 01 1987 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $4,150 $4,392 Not Implemented
RU0009 # 05 Y:1987 05 1987 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $140 $300 Not Implemented
OR0009 # 06 Y:1987 06 1987 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $6,380 $2,300 Not Implemented
OR0010 # 03 Y:1987 03 1987 INCREASE AMOUNT OF CONDENSATE RETURNED $31,778 $2,900 Implemented
OR0011 # 02 Y:1987 02 1987 INSULATE BARE EQUIPMENT $389 $96 Implemented
OR0011 # 03 Y:1987 03 1987 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,474 $0 Not Implemented
OR0011 # 04 Y:1987 04 1987 INSTALL / REPAIR INSULATION ON STEAM LINES $3,519 $1,536 Implemented
OR0011 # 05 Y:1987 05 1987 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,969 $3,600 Not Implemented
OR0011 # 06 Y:1987 06 1987 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $4,103 $3,000 Not Implemented
OR0006 # 08 Y:1987 08 1987 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $6,089 $13,772 Not Implemented
OR0007 # 04 Y:1987 04 1987 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,646 $1,700 Not Implemented
OR0007 # 05 Y:1987 05 1987 INSULATE BARE EQUIPMENT $677 $168 Not Implemented
OR0007 # 06 Y:1987 06 1987 RECOVER WASTE HEAT FROM EQUIPMENT $7,065 $5,550 Not Implemented
OR0008 # 10 Y:1987 10 1987 INSULATE BARE EQUIPMENT $2,608 $2,691 Implemented
CO0098 # 06 Y:1987 06 1987 RECOVER WASTE HEAT FROM EQUIPMENT $664 $1,200 Implemented
AT0088 # 04 Y:1987 04 1987 INSULATE BARE EQUIPMENT $854 $800 Implemented
GT0326 # 04 Y:1987 04 1987 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $458 $3,000 Not Implemented
GT0326 # 05 Y:1987 05 1987 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $1,320 $480 Not Implemented
GT0326 # 06 Y:1987 06 1987 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $1,440 $500 Implemented
KU0233 # 01 Y:1987 01 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,808 $5,500 Not Implemented
KU0234 # 02 Y:1987 02 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,993 $8,000 Not Implemented
KU0234 # 03 Y:1987 03 1987 RECOVER WASTE HEAT FROM EQUIPMENT $5,345 $4,000 Implemented