Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

69

matching recommendations
Reset
ARC 2.26 COOLING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0205 # 06 Y:1994 06 1994 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $845 $0 Implemented
OR0205 # 05 Y:1994 05 1994 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $4,373 $14,067 Not Implemented
SD0080 # 17 Y:1994 17 1994 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $6,243 $20 Not Implemented
OR0204 # 02 Y:1994 02 1994 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $912 $3,000 Implemented
SD0080 # 16 Y:1994 16 1994 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $28,339 $25,000 Implemented
KU0426 # 01 Y:1994 01 1994 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $4,888 $2,500 Not Implemented
OR0204 # 01 Y:1994 01 1994 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $11,122 $5,000 Implemented
GT0521 # 05 Y:1994 05 1994 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $6,070 $4,600 Not Implemented
IA0081 # 01 Y:1994 01 1994 UTILIZE A LESS EXPENSIVE COOLING METHOD $4,823 $7,982 Implemented
NC0021 # 04 Y:1994 04 1994 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $5,719 $8,750 Not Implemented
HO0066 # 05 Y:1994 05 1994 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $7,470 $10,000 Not Implemented
MA0296 # 04 Y:1994 04 1994 UTILIZE A LESS EXPENSIVE COOLING METHOD $3,525 $7,280 Not Implemented
AS0111 # 06 Y:1994 06 1994 USE CASCADE SYSTEM OF RECIRCULATING DURING COLD WEATHER TO AVOID SUB-COOLING $4,008 $12,000 n/a
WI0201 # 01 Y:1994 01 1994 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $12,890 $42,825 Not Implemented
SD0071 # 04 Y:1994 04 1994 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $16,815 $8,515 Not Implemented
WI0199 # 04 Y:1994 04 1994 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,819 $15,000 Not Implemented
CO0291 # 07 Y:1994 07 1994 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $370 $240 Implemented
WI0198 # 01 Y:1994 01 1994 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $10,895 $20,000 Not Implemented
AM0196 # 03 Y:1994 03 1994 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $22,270 $51,520 Not Implemented