Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47,417
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0878 # 07 Y:2014 | 07 | 2014 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $3,821 | $2,573 | Implemented |
OK0878 # 08 Y:2014 | 08 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $18,835 | $13,760 | Not Implemented |
OK0878 # 11 Y:2014 | 11 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,371 | $13,908 | Implemented |
OK0878 # 12 Y:2014 | 12 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,570 | $55,638 | Implemented |
OK0878 # 13 Y:2014 | 13 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $217 | $1,073 | Not Implemented |
SD0482 # 02 Y:2014 | 02 | 2014 | USE PHOTOCELL CONTROLS | $1,780 | $3,145 | Implemented |
MA0727 # 02 Y:2014 | 02 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $52,084 | $127,730 | Not Implemented |
UK1401 # 06 Y:2014 | 06 | 2014 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,590 | $7,550 | Not Implemented |
UK1401 # 07 Y:2014 | 07 | 2014 | INSTALL OCCUPANCY SENSORS | $2,274 | $860 | Not Implemented |
UK1401 # 12 Y:2014 | 12 | 2014 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $666 | $86 | Not Implemented |
UK1401 # 13 Y:2014 | 13 | 2014 | USE PHOTOCELL CONTROLS | $249 | $222 | Not Implemented |
UK1401 # 14 Y:2014 | 14 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $53 | $65 | Not Implemented |
UK1401 # 15 Y:2014 | 15 | 2014 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $68 | $0 | Not Implemented |
BS0031 # 05 Y:2014 | 05 | 2014 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $361 | $467 | Implemented |
BS0031 # 06 Y:2014 | 06 | 2014 | INSTALL OCCUPANCY SENSORS | $242 | $660 | Implemented |
AM0655 # 07 Y:2014 | 07 | 2014 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,600 | $0 | Not Implemented |
AM0655 # 08 Y:2014 | 08 | 2014 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,130 | $0 | Implemented |
UA0117 # 01 Y:2014 | 01 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $116,327 | $120 | Not Implemented |
UA0117 # 03 Y:2014 | 03 | 2014 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $14,760 | $21,000 | Implemented |
UA0117 # 04 Y:2014 | 04 | 2014 | INSTALL OCCUPANCY SENSORS | $4,219 | $1,139 | Not Implemented |
OR0628 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,875 | $1,293 | Not Implemented |
SF0446 # 07 Y:2014 | 07 | 2014 | INSTALL OCCUPANCY SENSORS | $7,640 | $28,695 | Implemented |
SF0446 # 08 Y:2014 | 08 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,552 | $15,048 | Not Implemented |
DL0126 # 10 Y:2014 | 10 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,400 | $7,400 | Implemented |
MZ0138 # 04 Y:2014 | 04 | 2014 | AIR CONDITION ONLY SPACE NECESSARY | $3,570 | $0 | Not Implemented |