Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47,417
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0897 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,409 | $5,020 | Not Implemented |
UD0897 # 07 Y:2014 | 07 | 2014 | ADD AREA LIGHTING SWITCHES | $664 | $600 | Not Implemented |
UD0897 # 08 Y:2014 | 08 | 2014 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $142 | $900 | Not Implemented |
UD0897 # 09 Y:2014 | 09 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $22,517 | $48,000 | Not Implemented |
SF0443 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,897 | $24,840 | Not Implemented |
SF0443 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,886 | $16,744 | Not Implemented |
LE0371 # 02 Y:2014 | 02 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $3,996 | $0 | Not Implemented |
LE0371 # 07 Y:2014 | 07 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $18,293 | $2,740 | Not Implemented |
LE0371 # 14 Y:2014 | 14 | 2014 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $1,091 | $4,140 | Implemented |
LE0371 # 15 Y:2014 | 15 | 2014 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,748 | $21,000 | Not Implemented |
LE0371 # 17 Y:2014 | 17 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $71 | $350 | Not Implemented |
IP0022 # 03 Y:2014 | 03 | 2014 | INSTALL OCCUPANCY SENSORS | $631 | $212 | Not Implemented |
IP0022 # 04 Y:2014 | 04 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,868 | $2,394 | Not Implemented |
IP0022 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $870 | $1,590 | Implemented |
CO0682 # 02 Y:2014 | 02 | 2014 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $42,490 | $93,580 | Not Implemented |
CO0682 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,860 | $5,750 | Not Implemented |
CO0682 # 04 Y:2014 | 04 | 2014 | INSTALL OCCUPANCY SENSORS | $1,250 | $1,240 | Not Implemented |
SU0357 # 02 Y:2014 | 02 | 2014 | INSTALL OCCUPANCY SENSORS | $1,140 | $521 | Not Implemented |
SU0357 # 03 Y:2014 | 03 | 2014 | DISCONNECT BALLASTS | $96 | $0 | Implemented |
SU0357 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $595 | $532 | Implemented |
IP0021 # 05 Y:2014 | 05 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,336 | $0 | Not Implemented |
IP0021 # 06 Y:2014 | 06 | 2014 | INSTALL OCCUPANCY SENSORS | $222 | $118 | Implemented |
AM0650 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,050 | $605 | Implemented |
AM0650 # 07 Y:2014 | 07 | 2014 | INSTALL OCCUPANCY SENSORS | $540 | $550 | Implemented |
CO0681 # 03 Y:2014 | 03 | 2014 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $175,400 | $229,810 | Implemented |