Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47,477
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0062 # 05 Y:2011 | 05 | 2011 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $866 | $1,498 | Not Implemented |
MZ0062 # 12 Y:2011 | 12 | 2011 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $62 | $60 | Not Implemented |
MZ0062 # 13 Y:2011 | 13 | 2011 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $91 | $300 | Implemented |
BD0383 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,355 | $7,633 | Not Implemented |
BD0383 # 03 Y:2011 | 03 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $8,456 | $4,240 | Not Implemented |
BD0383 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $955 | $975 | Not Implemented |
AM0589 # 04 Y:2011 | 04 | 2011 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $4,230 | $370 | Implemented |
AM0589 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $205 | $225 | Implemented |
SU0301 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $2,477 | $2,028 | Implemented |
SU0301 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $377 | $487 | Not Implemented |
SD0503 # 03 Y:2010 | 03 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $24,981 | $0 | Implemented |
SD0503 # 04 Y:2010 | 04 | 2010 | INSTALL SKYLIGHTS | $7,467 | $22,980 | Implemented |
BD0376 # 07 Y:2010 | 07 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $7,210 | $9,000 | Not Implemented |
BD0376 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $989 | $1,727 | Implemented |
MS0361 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $86,285 | $59,157 | Implemented |
MZ0058 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $37,229 | $41,660 | Implemented |
MZ0058 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,522 | $22,400 | Implemented |
MZ0058 # 04 Y:2010 | 04 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $775 | $360 | Not Implemented |
LE0310 # 04 Y:2010 | 04 | 2010 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,986 | $2,500 | Implemented |
LE0310 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $875 | $300 | Not Implemented |
LE0310 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,896 | $4,636 | Not Implemented |
LE0310 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,402 | $7,308 | Not Implemented |
LE0310 # 09 Y:2010 | 09 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,927 | $30,380 | Not Implemented |
UD0828 # 02 Y:2010 | 02 | 2010 | DISCONNECT BALLASTS | $4,524 | $550 | Not Implemented |
UD0828 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $2,693 | $2,405 | Not Implemented |