Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47,479
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0408 # 13 Y:2010 | 13 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $415 | $1,118 | Not Implemented |
UA0054 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $86,265 | $71,625 | Not Implemented |
UA0054 # 04 Y:2010 | 04 | 2010 | USE PHOTOCELL CONTROLS | $2,443 | $1,893 | Not Implemented |
UA0054 # 07 Y:2010 | 07 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $4,372 | $3,230 | Implemented |
SD0428 # 01 Y:2010 | 01 | 2010 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,812 | $400 | Implemented |
SD0428 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $900 | $49 | Not Implemented |
SD0428 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $265 | $777 | Not Implemented |
OR0557 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,035 | $3,858 | Not Implemented |
MI0192 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $60,080 | $32,395 | Implemented |
MI0192 # 02 Y:2010 | 02 | 2010 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $39,832 | $41,440 | Not Implemented |
MI0192 # 03 Y:2010 | 03 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $37,971 | $1,020 | Implemented |
MI0192 # 06 Y:2010 | 06 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $17,417 | $1,020 | Implemented |
MI0192 # 09 Y:2010 | 09 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $10,176 | $9,650 | Implemented |
SF0387 # 03 Y:2010 | 03 | 2010 | USE PHOTOCELL CONTROLS | $7,756 | $1,353 | Implemented |
SF0387 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,874 | $1,627 | Implemented |
SF0387 # 09 Y:2010 | 09 | 2010 | INSTALL OCCUPANCY SENSORS | $920 | $2,132 | Implemented |
DL0055 # 06 Y:2010 | 06 | 2010 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $9,000 | $3,000 | Implemented |
DL0055 # 08 Y:2010 | 08 | 2010 | REDUCE VENTILATION AIR | $21,000 | $15,000 | Not Implemented |
DL0055 # 09 Y:2010 | 09 | 2010 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $23,200 | $15,000 | Not Implemented |
DL0055 # 11 Y:2010 | 11 | 2010 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $3,631 | $1,830 | Implemented |
GT0873 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,825 | $19,768 | Not Implemented |
GT0873 # 04 Y:2010 | 04 | 2010 | INSTALL OCCUPANCY SENSORS | $3,777 | $10,640 | Implemented |
GT0873 # 06 Y:2010 | 06 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,661 | $775 | Implemented |
BD0382 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,174 | $20,735 | Implemented |
BD0382 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $323 | $442 | Implemented |