Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47,481
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0290 # 01 Y:2009 | 01 | 2009 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $9,385 | $1,200 | Not Implemented |
LE0290 # 10 Y:2009 | 10 | 2009 | INSTALL OCCUPANCY SENSORS | $1,045 | $0 | Implemented |
LE0290 # 12 Y:2009 | 12 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $990 | $2,500 | Implemented |
OK0779 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,076 | $6,396 | Not Implemented |
OK0779 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,634 | $26,750 | Implemented |
OK0779 # 06 Y:2009 | 06 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,089 | $14,467 | Implemented |
OK0779 # 09 Y:2009 | 09 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $7,677 | $989 | Not Implemented |
UM0353 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $186,999 | $237,500 | Implemented |
UM0353 # 03 Y:2009 | 03 | 2009 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $22,477 | $22,000 | Not Implemented |
UM0353 # 07 Y:2009 | 07 | 2009 | INSTALL OCCUPANCY SENSORS | $9,160 | $6,330 | Not Implemented |
UM0353 # 08 Y:2009 | 08 | 2009 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $3,526 | $1,500 | Implemented |
IC0158 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $393 | $686 | Implemented |
IC0158 # 02 Y:2009 | 02 | 2009 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $177 | $0 | Implemented |
IC0158 # 07 Y:2009 | 07 | 2009 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,800 | $0 | Implemented |
LE0289 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,474 | $16,830 | Not Implemented |
LE0289 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,333 | $6,137 | Not Implemented |
LE0289 # 10 Y:2009 | 10 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,734 | $18,122 | Not Implemented |
MS0342 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,269 | $61,142 | Implemented |
MS0342 # 04 Y:2009 | 04 | 2009 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,113 | $0 | Implemented |
MS0342 # 05 Y:2009 | 05 | 2009 | INSTALL OCCUPANCY SENSORS | $602 | $1,212 | Not Implemented |
MS0342 # 06 Y:2009 | 06 | 2009 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $282 | $0 | Implemented |
SU0285 # 04 Y:2009 | 04 | 2009 | DISCONNECT BALLASTS | $2,387 | $0 | Not Implemented |
SU0285 # 07 Y:2009 | 07 | 2009 | INSTALL OCCUPANCY SENSORS | $4,200 | $2,508 | Implemented |
SU0285 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,299 | $18,800 | Implemented |
SU0285 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $214 | $183 | Not Implemented |