IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

558

matching recommendations
Reset
ARC 2.7 Building and Grounds
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AT0061 # 01 Y:1986 01 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,037 $2,585 Implemented
AT0061 # 03 Y:1986 03 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $273 $500 Not Implemented
CO0080 # 03 Y:1986 03 1986 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $7,035 $5,500 Not Implemented
OK0211 # 07 Y:1986 07 1986 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $6,220 $3,500 Not Implemented
TN0296 # 02 Y:1986 02 1986 INSTALL TIMERS AND/OR THERMOSTATS $6,477 $2,580 Implemented
TN0296 # 01 Y:1986 01 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $7,812 $25,175 Not Implemented
OK0212 # 03 Y:1986 03 1986 INSTALL TIMERS AND/OR THERMOSTATS $378 $450 Implemented
CO0080 # 13 Y:1986 13 1986 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $183 $80 Not Implemented
MA0079 # 03 Y:1986 03 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,763 $4,700 Implemented
OK0211 # 05 Y:1986 05 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $297 $294 Implemented
CO0062 # 12 Y:1986 12 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,862 $627 Implemented
CO0062 # 07 Y:1986 07 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $1,953 $2,824 Not Implemented
CO0062 # 03 Y:1986 03 1986 USE RADIANT HEATER FOR SPOT HEATING $7,549 $15,000 Not Implemented
CO0062 # 02 Y:1986 02 1986 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $10,638 $9,200 Implemented
OK0212 # 04 Y:1986 04 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,372 $212 Implemented
OK0211 # 06 Y:1986 06 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,305 $225 Implemented
AT0062 # 03 Y:1986 03 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,424 $4,759 Implemented
AT0062 # 02 Y:1986 02 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $3,994 $2,000 Implemented
AT0059 # 06 Y:1986 06 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $14,839 $5,000 Not Implemented
AT0058 # 03 Y:1986 03 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $2,928 $1,200 Implemented
AT0057 # 03 Y:1986 03 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $972 $1,500 Implemented
CO0080 # 14 Y:1986 14 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,631 $2,970 Implemented
OK0212 # 05 Y:1986 05 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,167 $1,575 Implemented
MA0078 # 05 Y:1986 05 1986 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $827 $240 Implemented
CO0080 # 11 Y:1986 11 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $768 $1,435 Not Implemented