Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

9,498

matching recommendations
Reset
ARC 2.72 SPACE CONDITIONING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0311 # 02 Y:1987 02 1987 INSTALL TIMERS AND/OR THERMOSTATS $5,954 $5,400 Implemented
OK0225 # 04 Y:1987 04 1987 USE RADIANT HEATER FOR SPOT HEATING $4,851 $16,900 Implemented
AT0078 # 01 Y:1987 01 1987 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $19,865 $4,500 Implemented
AT0079 # 06 Y:1987 06 1987 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $2,274 $3,000 Not Implemented
AM0002 # 02 Y:1987 02 1987 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $95,084 $60,000 Implemented
AT0074 # 04 Y:1987 04 1987 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,341 $1,500 Implemented
KU0226 # 07 Y:1987 07 1987 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,496 $3,000 Not Implemented
MA0095 # 05 Y:1987 05 1987 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $17,922 $6,400 Not Implemented
TN0308 # 03 Y:1987 03 1987 SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS $2,858 $3,500 Not Implemented
KU0223 # 08 Y:1987 08 1987 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $380 $0 Implemented
MA0092 # 02 Y:1987 02 1987 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $9,458 $425 Implemented
AM0003 # 02 Y:1987 02 1987 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $3,130 $0 Not Implemented
GT0315 # 02 Y:1987 02 1987 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $9,270 $13,000 Implemented
GT0313 # 01 Y:1987 01 1987 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $3,020 $85,000 Implemented
KU0225 # 02 Y:1987 02 1987 INSTALL TIMERS AND/OR THERMOSTATS $8,616 $500 Implemented
KU0226 # 09 Y:1987 09 1987 INSTALL TIMERS AND/OR THERMOSTATS $1,121 $0 Implemented
MA0090 # 04 Y:1987 04 1987 INSTALL TIMERS AND/OR THERMOSTATS $9,216 $935 Not Implemented
MA0091 # 04 Y:1987 04 1987 INSTALL TIMERS AND/OR THERMOSTATS $1,619 $400 Implemented
MA0095 # 06 Y:1987 06 1987 INSTALL TIMERS AND/OR THERMOSTATS $12,261 $1,700 Not Implemented
CO0091 # 03 Y:1987 03 1987 INSTALL TIMERS AND/OR THERMOSTATS $2,651 $175 Implemented
CO0091 # 08 Y:1987 08 1987 INSTALL TIMERS AND/OR THERMOSTATS $22,175 $1,682 Implemented
CO0092 # 11 Y:1987 11 1987 INSTALL TIMERS AND/OR THERMOSTATS $2,841 $474 Implemented
CO0092 # 10 Y:1987 10 1987 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,942 $4,800 Not Implemented
MA0094 # 03 Y:1987 03 1987 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $7,184 $9,600 Implemented
AM0001 # 05 Y:1987 05 1987 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $270 $15 Not Implemented