Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
936
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0125 # 02 Y:2007 | 02 | 2007 | INSTALL BACK-UP EQUIPMENT | $20,000 | $20,000 | Not Implemented |
LM0125 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,003 | $2,604 | Implemented |
LM0125 # 03 Y:2007 | 03 | 2007 | INSTALL EQUIPMENT TO MOVE PRODUCT | $89,704 | $11,000 | Implemented |
LM0125 # 04 Y:2007 | 04 | 2007 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $62,618 | $40,000 | Not Implemented |
LM0124 # 02 Y:2007 | 02 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,223 | $1,300 | Not Implemented |
LM0124 # 06 Y:2007 | 06 | 2007 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $34,678 | $2,000 | Implemented |
LM0124 # 05 Y:2007 | 05 | 2007 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $44,787 | $1,000 | Implemented |
LM0124 # 03 Y:2007 | 03 | 2007 | SCHEDULE DELIVERIES ACCORDING TO DEMAND | $151,200 | $2,000 | Implemented |
LM0124 # 04 Y:2007 | 04 | 2007 | INSTALL SENSORS TO DETECT AND AVOID JAMS | $15,120 | $1,400 | Not Implemented |
LM0124 # 01 Y:2007 | 01 | 2007 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $7,858 | $2,500 | Implemented |
LM0123 # 03 Y:2007 | 03 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,789 | $20,000 | Not Implemented |
LM0123 # 02 Y:2007 | 02 | 2007 | COVER OPEN TANKS | $7,790 | $1,800 | Not Implemented |
LM0123 # 04 Y:2007 | 04 | 2007 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $37,630 | $1,000 | Not Implemented |
LM0123 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,533 | $33,000 | Not Implemented |
LM0122 # 01 Y:2007 | 01 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $42,830 | $89,250 | Not Implemented |
LM0122 # 04 Y:2007 | 04 | 2007 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $19,128 | $5,500 | Implemented |
LM0122 # 02 Y:2007 | 02 | 2007 | ISOLATE HOT OR COLD EQUIPMENT | $814 | $2,000 | Not Implemented |
LM0122 # 03 Y:2007 | 03 | 2007 | INSTALL OCCUPANCY SENSORS | $1,465 | $3,975 | Not Implemented |
LM0122 # 05 Y:2007 | 05 | 2007 | MODIFY WORKLOAD | $9,311 | $4,850 | Implemented |
LM0121 # 01 Y:2006 | 01 | 2006 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $183,000 | $2,160 | Not Implemented |
LM0121 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,390 | $10,233 | Implemented |
LM0121 # 04 Y:2006 | 04 | 2006 | INSULATE BARE EQUIPMENT | $3,734 | $3,100 | Implemented |
LM0121 # 02 Y:2006 | 02 | 2006 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $91,500 | $200 | Not Implemented |
LM0119 # 05 Y:2006 | 05 | 2006 | CONDENSE OPERATION INTO ONE BUILDING | $39,440 | $0 | Not Implemented |
LM0119 # 02 Y:2006 | 02 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $746 | $0 | Not Implemented |