IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,766

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0121 # 06 Y:1988 06 1988 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $7,432 $6,690 Implemented
MA0117 # 02 Y:1988 02 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $625 $105 Implemented
MA0117 # 04 Y:1988 04 1988 INSTALL TIMERS AND/OR THERMOSTATS $240 $75 Implemented
MA0117 # 05 Y:1988 05 1988 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $340 $0 Implemented
MA0118 # 02 Y:1988 02 1988 REPAIR OR REPLACE STEAM TRAPS $8,138 $1,464 Implemented
MA0118 # 03 Y:1988 03 1988 INSTALL / REPAIR INSULATION ON STEAM LINES $2,626 $930 Implemented
MA0118 # 04 Y:1988 04 1988 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $743 $990 Implemented
MA0118 # 06 Y:1988 06 1988 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,658 $377 Implemented
MA0118 # 09 Y:1988 09 1988 USE OPTIMUM THICKNESS INSULATION $2,742 $2,160 Implemented
MA0114 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,356 $10,888 Implemented
MA0114 # 02 Y:1988 02 1988 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $3,355 $8,000 Implemented
MA0114 # 04 Y:1988 04 1988 OPTIMIZE PLANT POWER FACTOR $9,930 $23,000 Implemented
MA0114 # 07 Y:1988 07 1988 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,077 $600 Implemented
MA0114 # 09 Y:1988 09 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $465 $450 Implemented
MA0112 # 02 Y:1988 02 1988 INSTALL SET-BACK TIMERS $534 $0 Implemented
MA0113 # 01 Y:1988 01 1988 REDUCE VENTILATION AIR $1,763 $8 Implemented
MA0113 # 02 Y:1988 02 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $474 $0 Implemented
MA0111 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,588 $3,792 Implemented
MA0111 # 03 Y:1988 03 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $311 $78 Implemented
MA0111 # 06 Y:1988 06 1988 INSTALL STORM WINDOWS AND DOORS $1,177 $2,400 Implemented
MA0111 # 08 Y:1988 08 1988 USE DEMAND CONTROLLER OR LOAD SHEDDER $30,000 $940 Implemented
MA0109 # 02 Y:1987 02 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $383 $87 Implemented
MA0109 # 04 Y:1987 04 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $122 $75 Implemented
MA0106 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $334 $129 Implemented
MA0106 # 03 Y:1987 03 1987 REPAIR OR REPLACE STEAM TRAPS $1,717 $3,445 Implemented