Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
44
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0257 # 09 Y:1999 | 09 | 1999 | REDUCE SCRAP PRODUCTION | $66,200 | $20,000 | Implemented |
ME0257 # 07 Y:1999 | 07 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $702 | $300 | Implemented |
ME0257 # 06 Y:1999 | 06 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $920 | $20 | Implemented |
ME0257 # 05 Y:1999 | 05 | 1999 | INSULATE BARE EQUIPMENT | $2,268 | $879 | Implemented |
ME0257 # 04 Y:1999 | 04 | 1999 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,980 | $6,797 | Implemented |
ME0257 # 03 Y:1999 | 03 | 1999 | ADVERTISE PRODUCT OR SERVICE | $2,993 | $0 | Implemented |
ME0257 # 02 Y:1999 | 02 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,900 | $1,000 | Implemented |
ME0257 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,536 | $21,031 | Implemented |
ME0256 # 06 Y:1999 | 06 | 1999 | INSULATE BARE EQUIPMENT | $325 | $400 | Implemented |
ME0256 # 02 Y:1999 | 02 | 1999 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $4,700 | $900 | Implemented |
ME0256 # 03 Y:1999 | 03 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,563 | $2,500 | Implemented |
ME0256 # 04 Y:1999 | 04 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $512 | $185 | Implemented |
ME0256 # 05 Y:1999 | 05 | 1999 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $337 | $400 | Implemented |
ME0256 # 07 Y:1999 | 07 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $319 | $590 | Implemented |
ME0256 # 08 Y:1999 | 08 | 1999 | INSULATE BARE EQUIPMENT | $236 | $93 | Implemented |
ME0251 # 06 Y:1998 | 06 | 1998 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $160,875 | $31,200 | Implemented |
ME0251 # 05 Y:1998 | 05 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $448 | $0 | Implemented |
ME0251 # 04 Y:1998 | 04 | 1998 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,020 | $400 | Implemented |
ME0251 # 03 Y:1998 | 03 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,240 | $2,100 | Implemented |
ME0251 # 01 Y:1998 | 01 | 1998 | INSULATE BARE EQUIPMENT | $2,487 | $600 | Implemented |
ME0250 # 10 Y:1998 | 10 | 1998 | PAY BILLS ON TIME TO AVOID LATE FEES | $430 | $184 | Implemented |
ME0250 # 11 Y:1998 | 11 | 1998 | INSULATE BARE EQUIPMENT | $427 | $0 | Implemented |
ME0249 # 05 Y:1998 | 05 | 1998 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $357 | $240 | Implemented |
ME0248 # 04 Y:1998 | 04 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,127 | $6,773 | Implemented |
ME0248 # 05 Y:1998 | 05 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $6,421 | $1,958 | Implemented |