Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
82
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0285 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $464 | $142 | Implemented |
OR0285 # 01 Y:1996 | 01 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $33,432 | $0 | Implemented |
OR0285 # 03 Y:1996 | 03 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $36,382 | $10,450 | Implemented |
OR0285 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,671 | $15,663 | Implemented |
OR0284 # 03 Y:1996 | 03 | 1996 | INSULATE FEEDWATER TANK | $291 | $155 | Implemented |
OR0284 # 01 Y:1996 | 01 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $35,224 | $10,450 | Implemented |
OR0284 # 02 Y:1996 | 02 | 1996 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,074 | $516 | Implemented |
OR0283 # 01 Y:1996 | 01 | 1996 | USE MINIMUM STEAM OPERATING PRESSURE | $1,474 | $0 | Implemented |
OR0283 # 02 Y:1996 | 02 | 1996 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $715 | $1,566 | Implemented |
OR0283 # 07 Y:1996 | 07 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,032 | $29,713 | Implemented |
OR0282 # 04 Y:1996 | 04 | 1996 | UPGRADE CONTROLS ON COMPRESSORS | $280 | $300 | Implemented |
OR0282 # 02 Y:1996 | 02 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $240 | $0 | Implemented |
OR0282 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $212 | $664 | Implemented |
OR0281 # 08 Y:1996 | 08 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $120 | $0 | Implemented |
OR0281 # 02 Y:1996 | 02 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,000 | $128,480 | Implemented |
OR0281 # 07 Y:1996 | 07 | 1996 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $10,430 | $50,000 | Implemented |
OR0281 # 01 Y:1996 | 01 | 1996 | KEEP BOILER TUBES CLEAN | $10,640 | $800 | Implemented |
OR0281 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,450 | $34,810 | Implemented |
OR0281 # 04 Y:1996 | 04 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,510 | $11,180 | Implemented |
OR0280 # 01 Y:1996 | 01 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,576 | $0 | Implemented |
OR0280 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,986 | $15,828 | Implemented |
OR0279 # 05 Y:1996 | 05 | 1996 | KEEP BOILER TUBES CLEAN | $1,349 | $1,500 | Implemented |
OR0278 # 02 Y:1996 | 02 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,734 | $1,778 | Implemented |
OR0278 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,832 | $11,104 | Implemented |
OR0278 # 03 Y:1996 | 03 | 1996 | UPGRADE CONTROLS ON COMPRESSORS | $8,541 | $2,640 | Implemented |