Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,732
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0468 # 02 Y:2016 | 02 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,680 | $2,150 | Not Implemented |
UM0468 # 01 Y:2016 | 01 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $695 | $1,500 | Not Implemented |
UM0466 # 05 Y:2016 | 05 | 2016 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $387 | $400 | Implemented |
UM0466 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,085 | $21,450 | Not Implemented |
UM0466 # 03 Y:2016 | 03 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,784 | $1,000 | Implemented |
UM0466 # 02 Y:2016 | 02 | 2016 | INSULATE BARE EQUIPMENT | $1,801 | $1,000 | Implemented |
UM0466 # 01 Y:2016 | 01 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,747 | $2,000 | Not Implemented |
UM0465 # 05 Y:2016 | 05 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,361 | $150 | Not Implemented |
UM0465 # 04 Y:2016 | 04 | 2016 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,573 | $0 | Not Implemented |
UM0465 # 03 Y:2016 | 03 | 2016 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $485 | $1,029 | Not Implemented |
UM0465 # 02 Y:2016 | 02 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,640 | $2,000 | Not Implemented |
UM0465 # 01 Y:2016 | 01 | 2016 | INSTALL OCCUPANCY SENSORS | $3,158 | $5,250 | Not Implemented |
UM0463 # 04 Y:2015 | 04 | 2015 | CONVERT TO OXYFUEL BURNERS | $3,052,580 | $1,000,000 | Not Implemented |
UM0463 # 03 Y:2015 | 03 | 2015 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $12,674 | $4,000 | Not Implemented |
UM0463 # 02 Y:2015 | 02 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $150,724 | $565,274 | Implemented |
UM0463 # 01 Y:2015 | 01 | 2015 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $1,052,850 | $1,822,453 | Not Implemented |
UM0462 # 06 Y:2015 | 06 | 2015 | INSTALL OCCUPANCY SENSORS | $2,455 | $4,800 | Not Implemented |
UM0462 # 05 Y:2015 | 05 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,224 | $1,000 | Not Implemented |
UM0462 # 04 Y:2015 | 04 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $17,638 | $4,500 | Not Implemented |
UM0462 # 03 Y:2015 | 03 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $23,500 | $8,000 | Not Implemented |
UM0462 # 02 Y:2015 | 02 | 2015 | HEAT WATER WITH EXHAUST HEAT | $16,361 | $20,000 | Not Implemented |
UM0462 # 01 Y:2015 | 01 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,802 | $7,405 | Not Implemented |
UM0461 # 02 Y:2015 | 02 | 2015 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,840 | $475 | Not Implemented |
UM0461 # 01 Y:2015 | 01 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $940 | $800 | Not Implemented |
UM0461 # 03 Y:2015 | 03 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,057 | $2,000 | Implemented |