Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

523

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UW0013 # 01 Y:2008 01 2008 SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS $3,676 $593 Not Implemented
UW0013 # 02 Y:2008 02 2008 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,365 $130 Not Implemented
UW0013 # 03 Y:2008 03 2008 UPGRADE OBSOLETE EQUIPMENT $1,913 $6,000 Not Implemented
UW0013 # 04 Y:2008 04 2008 USE SOLAR HEAT FOR HEAT $1,498 $4,250 Not Implemented
UW0013 # 05 Y:2008 05 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $544 $0 Implemented
UW0013 # 06 Y:2008 06 2008 INSTALL OCCUPANCY SENSORS $522 $1,787 Not Implemented
UW0011 # 01 Y:2008 01 2008 REPLACE BOILER $8,882 $23,870 Not Implemented
UW0011 # 02 Y:2008 02 2008 INSULATE BARE EQUIPMENT $7,908 $15,906 Not Implemented
UW0011 # 03 Y:2008 03 2008 SELL COMBUSTIBLE WASTE $5,774 $0 Not Implemented
UW0011 # 04 Y:2008 04 2008 USE SOLAR HEAT TO HEAT WATER $5,523 $20,275 Not Implemented
UW0011 # 05 Y:2008 05 2008 INSTALL SKYLIGHTS $5,089 $26,250 Not Implemented
UW0011 # 06 Y:2008 06 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,444 $0 Not Implemented
UW0011 # 07 Y:2008 07 2008 INSTALL OCCUPANCY SENSORS $1,476 $300 Not Implemented
UW0010 # 01 Y:2008 01 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $14,108 $4,160 Implemented
UW0010 # 02 Y:2008 02 2008 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $7,398 $75,533 Not Implemented
UW0010 # 03 Y:2008 03 2008 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $5,340 $3,000 Not Implemented
UW0009 # 01 Y:2007 01 2007 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $93,799 $136,650 Not Implemented
UW0009 # 02 Y:2007 02 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $27,889 $1,720 Not Implemented
UW0009 # 03 Y:2007 03 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $28,369 $138,420 Not Implemented
UW0009 # 04 Y:2007 04 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $8,031 $7,140 Implemented
UW0009 # 05 Y:2007 05 2007 RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION $11,196 $2,080 Not Implemented
UW0009 # 06 Y:2007 06 2007 IMPROVE COMBUSTION CONTROL CAPABILITY $4,114 $3,000 Not Implemented
UW0009 # 07 Y:2007 07 2007 DEVELOP A REPAIR/REPLACE POLICY $3,371 $1,984 Implemented
UW0008 # 01 Y:2007 01 2007 USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS $136,932 $492,147 Implemented
UW0008 # 02 Y:2007 02 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $24,830 $81,585 Implemented