Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,628
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0258 # 11 Y:2003 | 11 | 2003 | INSULATE BARE EQUIPMENT | $7,852 | $2,734 | Implemented |
WV0258 # 12 Y:2003 | 12 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,489 | $200 | Implemented |
WV0258 # 13 Y:2003 | 13 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,945 | $250 | Implemented |
UD0662 # 01 Y:2003 | 01 | 2003 | IMPROVE SPACE COMFORT CONDITIONING | $4,100 | $5,938 | Implemented |
UD0662 # 11 Y:2003 | 11 | 2003 | USE PHOTOCELL CONTROLS | $172 | $154 | Implemented |
UD0660 # 02 Y:2003 | 02 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $31,779 | $0 | Implemented |
UD0660 # 05 Y:2003 | 05 | 2003 | REDUCE VENTILATION AIR | $8,388 | $15,000 | Implemented |
UD0660 # 08 Y:2003 | 08 | 2003 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $5,026 | $8,400 | Implemented |
UD0660 # 12 Y:2003 | 12 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,763 | $3,318 | Implemented |
UD0660 # 15 Y:2003 | 15 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,443 | $1,000 | Implemented |
UD0660 # 16 Y:2003 | 16 | 2003 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $1,260 | $0 | Implemented |
UD0660 # 20 Y:2003 | 20 | 2003 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $150 | $0 | Implemented |
WV0256 # 01 Y:2003 | 01 | 2003 | INSULATE BARE EQUIPMENT | $969 | $1,023 | Implemented |
WV0256 # 02 Y:2003 | 02 | 2003 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,359 | $400 | Implemented |
WV0256 # 03 Y:2003 | 03 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $82 | $1,000 | Implemented |
WV0256 # 05 Y:2003 | 05 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $541 | $50 | Implemented |
WV0256 # 07 Y:2003 | 07 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $267 | $750 | Implemented |
WV0256 # 08 Y:2003 | 08 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $255 | $0 | Implemented |
WV0256 # 09 Y:2003 | 09 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $752 | $40 | Implemented |
WV0256 # 10 Y:2003 | 10 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $1,043 | $1,000 | Implemented |
WV0255 # 02 Y:2003 | 02 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,774 | $100 | Implemented |
WV0255 # 05 Y:2003 | 05 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,236 | $2,025 | Implemented |
WV0255 # 06 Y:2003 | 06 | 2003 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $42,452 | $2,000 | Implemented |
WV0255 # 08 Y:2003 | 08 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,094 | $1,000 | Implemented |
WV0255 # 09 Y:2003 | 09 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,875 | $0 | Implemented |