Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,486

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LM0038 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $337 $250 Implemented
LM0038 # 02 Y:2002 02 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,001 $200 Implemented
LM0038 # 03 Y:2002 03 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $13,662 $1,100 Implemented
LM0038 # 04 Y:2002 04 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,190 $90 Implemented
LM0038 # 05 Y:2002 05 2002 ADD AREA LIGHTING SWITCHES $898 $800 Implemented
LM0038 # 06 Y:2002 06 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,602 $60 Implemented
SD0297 # 02 Y:2002 02 2002 INSTALL OCCUPANCY SENSORS $15,891 $500 Implemented
SD0297 # 03 Y:2002 03 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,846 $440 Implemented
SD0297 # 04 Y:2002 04 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,292 $500 Implemented
SD0296 # 02 Y:2002 02 2002 TURN OFF EQUIPMENT WHEN NOT IN USE $10,981 $1,000 Implemented
SD0296 # 05 Y:2002 05 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $878 $0 Implemented
SD0296 # 09 Y:2002 09 2002 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,019 $5,500 Implemented
SD0296 # 10 Y:2002 10 2002 INSTALL REDUNDANT EQUIPMENT TO AVOID LOSSES CAUSED BY EQUIPMENT FAILURE AND ROUTINE MAINTENANCE $2,019 $5,800 Implemented
LM0037 # 03 Y:2002 03 2002 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,259 $1,700 Implemented
SF0237 # 01 Y:2002 01 2002 REPAIR AND ELIMINATE STEAM LEAKS $7,124 $0 Implemented
SF0237 # 02 Y:2002 02 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,874 $0 Implemented
SF0237 # 04 Y:2002 04 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,539 $1,024 Implemented
SF0237 # 05 Y:2002 05 2002 INSULATE BARE EQUIPMENT $8,315 $6,667 Implemented
SF0237 # 07 Y:2002 07 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $24,405 $58,318 Implemented
SF0237 # 09 Y:2002 09 2002 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $3,489 $0 Implemented
LM0036 # 01 Y:2002 01 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $203,445 $95,480 Implemented
LM0036 # 02 Y:2002 02 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,227 $1,335 Implemented
LM0036 # 03 Y:2002 03 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $15,015 $550 Implemented
LM0036 # 05 Y:2002 05 2002 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $21,342 $4,800 Implemented
LM0036 # 08 Y:2002 08 2002 INSTALL SENSORS TO DETECT AND AVOID JAMS $101,250 $15,800 Implemented