Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,052

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0010 # 06 Y:2008 06 2008 UPGRADE CONTROLS ON COMPRESSORS $2,625 $5,250 Implemented
TT0023 # 05 Y:2008 05 2008 REPAIR AND ELIMINATE STEAM LEAKS $55,100 $20,000 Implemented
TT0023 # 06 Y:2008 06 2008 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $37,200 $1,000 Implemented
TT0023 # 07 Y:2008 07 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $13,600 $8,310 Implemented
TT0023 # 08 Y:2008 08 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $12,275 $4,900 Implemented
TT0023 # 09 Y:2008 09 2008 REPAIR OR REPLACE STEAM TRAPS $1,750 $1,600 Implemented
UD0782 # 01 Y:2008 01 2008 TURN OFF EQUIPMENT WHEN NOT IN USE $28,951 $0 Implemented
UD0782 # 02 Y:2008 02 2008 INSTALL OCCUPANCY SENSORS $5,748 $6,528 Implemented
UD0782 # 04 Y:2008 04 2008 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $4,245 $0 Implemented
UD0782 # 06 Y:2008 06 2008 ADD AREA LIGHTING SWITCHES $3,233 $10,000 Implemented
UD0782 # 07 Y:2008 07 2008 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,243 $1,800 Implemented
UD0782 # 09 Y:2008 09 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,907 $1,000 Implemented
UD0781 # 02 Y:2008 02 2008 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $9,566 $5,000 Implemented
UD0781 # 04 Y:2008 04 2008 OPTIMIZE PLANT POWER FACTOR $6,559 $9,000 Implemented
UD0781 # 06 Y:2008 06 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,285 $0 Implemented
UD0781 # 07 Y:2008 07 2008 IMPROVE COMBUSTION CONTROL CAPABILITY $2,508 $5,000 Implemented
UD0781 # 08 Y:2008 08 2008 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,162 $2,800 Implemented
UD0781 # 09 Y:2008 09 2008 INSTALL TIMERS AND/OR THERMOSTATS $2,146 $1,068 Implemented
UD0781 # 10 Y:2008 10 2008 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $1,794 $0 Implemented
UD0781 # 11 Y:2008 11 2008 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $800 $0 Implemented
UD0778 # 07 Y:2008 07 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,176 $0 Implemented
UD0778 # 08 Y:2008 08 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,563 $6,075 Implemented
UD0778 # 10 Y:2008 10 2008 INSTALL OCCUPANCY SENSORS $1,683 $4,305 Implemented
UD0773 # 01 Y:2008 01 2008 UPGRADE CONTROLS ON COMPRESSORS $79,805 $20,000 Implemented
UD0773 # 03 Y:2008 03 2008 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF $22,200 $15,000 Implemented