Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,628
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0421 # 04 Y:2011 | 04 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,529 | $2,469 | Implemented |
WV0421 # 07 Y:2011 | 07 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $4,203 | $841 | Implemented |
WV0421 # 08 Y:2011 | 08 | 2011 | INSULATE BARE EQUIPMENT | $4,166 | $1,910 | Implemented |
WV0421 # 10 Y:2011 | 10 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,731 | $21 | Implemented |
WV0421 # 12 Y:2011 | 12 | 2011 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $2,007 | $3,000 | Implemented |
WV0421 # 13 Y:2011 | 13 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,849 | $386 | Implemented |
WV0421 # 15 Y:2011 | 15 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $294 | $241 | Implemented |
WV0421 # 16 Y:2011 | 16 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $266 | $191 | Implemented |
UD0830 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $41,356 | $105,300 | Implemented |
UD0830 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,133 | $2,116 | Implemented |
UD0830 # 05 Y:2011 | 05 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,874 | $25 | Implemented |
UD0830 # 06 Y:2011 | 06 | 2011 | AVOID REWINDING MOTORS MORE THAN TWICE | $2,206 | $4,754 | Implemented |
UD0830 # 08 Y:2011 | 08 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $355 | $1,275 | Implemented |
UD0829 # 06 Y:2011 | 06 | 2011 | PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT | $1,738 | $5,214 | Implemented |
UD0829 # 07 Y:2011 | 07 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,121 | $500 | Implemented |
UD0829 # 08 Y:2011 | 08 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $547 | $500 | Implemented |
UD0828 # 06 Y:2010 | 06 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $17,796 | $62,106 | Implemented |
UD0828 # 07 Y:2010 | 07 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,431 | $1,200 | Implemented |
UD0828 # 10 Y:2010 | 10 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,710 | $500 | Implemented |
UD0828 # 13 Y:2010 | 13 | 2010 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $16,653 | $25 | Implemented |
UM0379 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,353 | $14,633 | Implemented |
UM0379 # 02 Y:2010 | 02 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,706 | $2,000 | Implemented |
UM0379 # 03 Y:2010 | 03 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $229 | $10 | Implemented |
UM0379 # 04 Y:2010 | 04 | 2010 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $9,060 | $1,500 | Implemented |
UM0379 # 05 Y:2010 | 05 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $7,283 | $9,861 | Implemented |