Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,631
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0708 # 05 Y:2004 | 05 | 2004 | INSTALL ROTATING CAROUSELS TO REDUCE SET-UP TIMES | $39,175 | $120,100 | Implemented |
UD0708 # 06 Y:2004 | 06 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $22,586 | $0 | Implemented |
UD0708 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,364 | $20,952 | Implemented |
UD0708 # 09 Y:2004 | 09 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,451 | $0 | Implemented |
UD0708 # 11 Y:2004 | 11 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,678 | $10,931 | Implemented |
UD0707 # 02 Y:2004 | 02 | 2004 | COVER OPEN TANKS | $27,270 | $4,326 | Implemented |
UD0707 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,956 | $31,342 | Implemented |
UD0707 # 07 Y:2004 | 07 | 2004 | INSTALL OCCUPANCY SENSORS | $1,158 | $245 | Implemented |
WV0307 # 03 Y:2004 | 03 | 2004 | ISOLATE HOT OR COLD EQUIPMENT | $3,113 | $755 | Implemented |
WV0307 # 08 Y:2004 | 08 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,767 | $53 | Implemented |
WV0307 # 09 Y:2004 | 09 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,177 | $210 | Implemented |
WV0307 # 10 Y:2004 | 10 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $1,513 | $271 | Implemented |
WV0307 # 11 Y:2004 | 11 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $903 | $0 | Implemented |
WV0307 # 12 Y:2004 | 12 | 2004 | USE OPTIMUM THICKNESS INSULATION | $278 | $380 | Implemented |
WV0307 # 13 Y:2004 | 13 | 2004 | INSULATE BARE EQUIPMENT | $262 | $260 | Implemented |
WV0307 # 14 Y:2004 | 14 | 2004 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,224 | $140 | Implemented |
WV0306 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $17,374 | $5,922 | Implemented |
WV0306 # 05 Y:2004 | 05 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,967 | $2,040 | Implemented |
WV0306 # 08 Y:2004 | 08 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $985 | $160 | Implemented |
WV0306 # 09 Y:2004 | 09 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $934 | $160 | Implemented |
WV0306 # 10 Y:2004 | 10 | 2004 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $796 | $40 | Implemented |
WV0306 # 12 Y:2004 | 12 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $696 | $3,480 | Implemented |
WV0306 # 13 Y:2004 | 13 | 2004 | INSTALL OCCUPANCY SENSORS | $395 | $800 | Implemented |
UD0705 # 01 Y:2004 | 01 | 2004 | OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS | $50,000 | $50,000 | Implemented |
UD0705 # 03 Y:2004 | 03 | 2004 | REDUCE SCRAP PRODUCTION | $12,990 | $0 | Implemented |