Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,628
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0705 # 11 Y:2004 | 11 | 2004 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $83 | $0 | Implemented |
UD0704 # 01 Y:2004 | 01 | 2004 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $10,368 | $0 | Implemented |
UD0704 # 03 Y:2004 | 03 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $846 | $900 | Implemented |
UD0704 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $668 | $700 | Implemented |
UD0704 # 06 Y:2004 | 06 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $504 | $0 | Implemented |
UD0704 # 07 Y:2004 | 07 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $223 | $500 | Implemented |
UD0703 # 01 Y:2004 | 01 | 2004 | REDUCE SCRAP PRODUCTION | $45,630 | $650 | Implemented |
UD0703 # 02 Y:2004 | 02 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $5,110 | $0 | Implemented |
UD0703 # 04 Y:2004 | 04 | 2004 | REDUCE OR ELIMINATE WASTE | $1,365 | $1,960 | Implemented |
UD0703 # 08 Y:2004 | 08 | 2004 | DISCONNECT BALLASTS | $392 | $206 | Implemented |
UD0703 # 10 Y:2004 | 10 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $289 | $126 | Implemented |
WV0302 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,584 | $3,731 | Implemented |
WV0302 # 02 Y:2004 | 02 | 2004 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $3,141 | $0 | Implemented |
WV0302 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,134 | $292 | Implemented |
WV0302 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,072 | $7,735 | Implemented |
WV0302 # 06 Y:2004 | 06 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,066 | $2,200 | Implemented |
WV0302 # 07 Y:2004 | 07 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,889 | $80 | Implemented |
WV0302 # 08 Y:2004 | 08 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,260 | $50 | Implemented |
WV0302 # 10 Y:2004 | 10 | 2004 | INSTALL OCCUPANCY SENSORS | $921 | $1,400 | Implemented |
WV0302 # 11 Y:2004 | 11 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $731 | $300 | Implemented |
WV0302 # 12 Y:2004 | 12 | 2004 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $28,080 | $100 | Implemented |
WV0302 # 13 Y:2004 | 13 | 2004 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $5,450 | $5,000 | Implemented |
WV0292 # 01 Y:2004 | 01 | 2004 | INSULATE BARE EQUIPMENT | $27,182 | $23,577 | Implemented |
WV0292 # 02 Y:2004 | 02 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $20,348 | $0 | Implemented |
WV0292 # 05 Y:2004 | 05 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $12,831 | $800 | Implemented |