Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,486
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0092 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,281 | $170 | Implemented |
LM0092 # 05 Y:2005 | 05 | 2005 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $62,655 | $140,000 | Implemented |
LM0092 # 06 Y:2005 | 06 | 2005 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $12,597 | $5,000 | Implemented |
LM0092 # 07 Y:2005 | 07 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $19,657 | $5,000 | Implemented |
LM0092 # 08 Y:2005 | 08 | 2005 | MAINTAIN/ENLARGE A STOCK OF SPARE PARTS | $36,180 | $5,000 | Implemented |
LM0092 # 09 Y:2005 | 09 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $98,438 | $100,000 | Implemented |
LM0092 # 10 Y:2005 | 10 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $14,473 | $100 | Implemented |
LM0092 # 11 Y:2005 | 11 | 2005 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $1,200 | $100 | Implemented |
SF0302 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $496 | $0 | Implemented |
SF0302 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $474 | $1,638 | Implemented |
SF0302 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $600 | $2,584 | Implemented |
SF0302 # 07 Y:2005 | 07 | 2005 | REUSE / RECYCLE/ SELL RUBBER PRODUCTS | $1,800 | $250 | Implemented |
SF0302 # 08 Y:2005 | 08 | 2005 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $1,200 | $0 | Implemented |
LM0091 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $709 | $300 | Implemented |
LM0091 # 02 Y:2005 | 02 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,029 | $683 | Implemented |
LM0091 # 03 Y:2005 | 03 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $764 | $240 | Implemented |
LM0091 # 05 Y:2005 | 05 | 2005 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $8,750 | $200 | Implemented |
LM0091 # 06 Y:2005 | 06 | 2005 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $16,875 | $2,150 | Implemented |
LM0091 # 07 Y:2005 | 07 | 2005 | MOVE PRODUCT USING MECHANICAL MEANS | $16,875 | $1,600 | Implemented |
SD0356 # 01 Y:2005 | 01 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $5,391 | $11,000 | Implemented |
SD0356 # 02 Y:2005 | 02 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,992 | $14,000 | Implemented |
SD0356 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,351 | $120 | Implemented |
LM0090 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $429 | $280 | Implemented |
LM0089 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,671 | $380 | Implemented |
LM0089 # 05 Y:2005 | 05 | 2005 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $26,400 | $0 | Implemented |