Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,215
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AR0178 # 04 Y:1999 | 04 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $341 | $0 | Implemented |
AR0178 # 05 Y:1999 | 05 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $12,779 | $19,000 | Implemented |
MA0452 # 01 Y:1999 | 01 | 1999 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $4,467 | $7,563 | Implemented |
MA0452 # 03 Y:1999 | 03 | 1999 | INSULATE BARE EQUIPMENT | $999 | $480 | Implemented |
MA0452 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $79 | $35 | Implemented |
SF0180 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,071 | $0 | Implemented |
SF0180 # 03 Y:1999 | 03 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,900 | $0 | Implemented |
SF0180 # 04 Y:1999 | 04 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $245 | $0 | Implemented |
SF0180 # 05 Y:1999 | 05 | 1999 | USE PHOTOCELL CONTROLS | $3,661 | $2,340 | Implemented |
SF0180 # 06 Y:1999 | 06 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $777 | $1,087 | Implemented |
SF0180 # 07 Y:1999 | 07 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $757 | $1,133 | Implemented |
SF0180 # 08 Y:1999 | 08 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $303 | $644 | Implemented |
SF0180 # 09 Y:1999 | 09 | 1999 | USE PHOTOCELL CONTROLS | $1,186 | $3,960 | Implemented |
SF0180 # 11 Y:1999 | 11 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $3,163 | $0 | Implemented |
OR0360 # 01 Y:1999 | 01 | 1999 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $9,585 | $2,840 | Implemented |
OR0360 # 02 Y:1999 | 02 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,909 | $0 | Implemented |
OR0360 # 05 Y:1999 | 05 | 1999 | SELL / OFFER BY-PRODUCT AS ANIMAL FEED | $17,520 | $2,000 | Implemented |
DS0150 # 03 Y:1999 | 03 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,552 | $15,640 | Implemented |
DS0150 # 04 Y:1999 | 04 | 1999 | REDUCE VENTILATION AIR | $32,699 | $30,301 | Implemented |
DS0150 # 05 Y:1999 | 05 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $29,468 | $37,220 | Implemented |
DS0150 # 07 Y:1999 | 07 | 1999 | $277 | $0 | Implemented | |
UL0235 # 02 Y:1999 | 02 | 1999 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,509 | $2,875 | Implemented |
AM0359 # 01 Y:1999 | 01 | 1999 | INSULATE BARE EQUIPMENT | $7,930 | $1,340 | Implemented |
AM0359 # 02 Y:1999 | 02 | 1999 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $4,270 | $0 | Implemented |
AM0359 # 03 Y:1999 | 03 | 1999 | $3,430 | $100 | Implemented |