Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
396
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NL0042 # 01 Y:2019 | 01 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,799 | $15,889 | Not Implemented |
NL0042 # 05 Y:2019 | 05 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,445 | $1,600 | Implemented |
NL0042 # 08 Y:2019 | 08 | 2019 | INSTALL OCCUPANCY SENSORS | $214 | $1,050 | Not Implemented |
NL0042 # 02 Y:2019 | 02 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,309 | $10,400 | Implemented |
NL0042 # 06 Y:2019 | 06 | 2019 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,989 | $2,400 | Not Implemented |
NL0036 # 05 Y:2019 | 05 | 2019 | INSTALL OCCUPANCY SENSORS | $674 | $4,353 | Not Implemented |
NL0036 # 04 Y:2019 | 04 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,508 | $500 | Implemented |
NL0036 # 03 Y:2019 | 03 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,715 | $2,905 | Implemented |
NL0036 # 02 Y:2019 | 02 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,862 | $7,623 | Implemented |
NL0036 # 01 Y:2019 | 01 | 2019 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $8,990 | $37,155 | Implemented |
NL0035 # 03 Y:2019 | 03 | 2019 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $8,170 | $35,828 | Implemented |
NL0035 # 05 Y:2019 | 05 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,450 | $1,600 | Implemented |
NL0035 # 02 Y:2019 | 02 | 2019 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $16,935 | $18,980 | Not Implemented |
NL0035 # 01 Y:2019 | 01 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $36,555 | $34,820 | Implemented |
NL0035 # 04 Y:2019 | 04 | 2019 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,867 | $0 | Implemented |
NL0035 # 06 Y:2019 | 06 | 2019 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $825 | $2,025 | Implemented |
NL0023 # 04 Y:2018 | 04 | 2018 | METER WASTE WATER | $320 | $0 | Not Implemented |
NL0023 # 03 Y:2018 | 03 | 2018 | RECOVER AND REUSE WASTE MATERIAL | $2,484 | $7,000 | Implemented |
NL0023 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,027 | $132,430 | Implemented |
NL0023 # 02 Y:2018 | 02 | 2018 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,100 | $0 | Not Implemented |
IA0563 # 04 Y:2016 | 04 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,656 | $560 | Implemented |
IA0563 # 08 Y:2016 | 08 | 2016 | INSTALL OCCUPANCY SENSORS | $570 | $2,800 | Implemented |
IA0563 # 07 Y:2016 | 07 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,182 | $1,900 | Implemented |
IA0563 # 06 Y:2016 | 06 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,484 | $700 | Implemented |
IA0563 # 03 Y:2016 | 03 | 2016 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,852 | $13,275 | Implemented |